Comparison of transcranial brain tissue perfusion images between ultraharmonic, second harmonic, and power harmonic imaging.
نویسندگان
چکیده
BACKGROUND AND PURPOSE To clarify optimal brain tissue perfusion images visualized by transcranial ultrasound harmonic imaging, we compared gray-scale integrated backscatter (IBS) images of new ultraharmonic imaging (UHI) and conventional second harmonic imaging (SHI) with power harmonic imaging (PHI) (harmonic B-mode with harmonic power Doppler images) in 10 patients with and 4 without a temporal skull. METHODS Using a SONOS 5500 (Philips), we evaluated transient response images taken after a bolus Levovist injection at a horizontal diencephalic plane via temporal windows. Based on transmitting/receiving frequencies (MHz), 4 imaging procedures using an S3 transducer (SHI2.6 [1.3/2.6], UHI [1.3/3.6], PHI2.6 [1.3/2.6], and PHI3.2 [1.6/3.2]) and 2 imaging procedures using an S4 transducer (SHI3.6 [1.8/3.6] and PHI3.6 [1.8/3.6]) were compared in terms of size and location, peak intensity (PI), contrast area demarcation, and background image quality. RESULTS In intact skull cases, gray-scale imaging tended to show larger contrast areas than PHI. A large contrast area was most frequently observed in SHI2.6 images, despite there being more high-PI cases in UHI. No contrast area with unclear background was observed in a few cases. In craniectomized cases, all contrast images tended to have large and high PI compared with the intact skull cases. PHI, particularly PHI3.6, demonstrated sharper demarcation and a clearer background than gray-scale imaging. CONCLUSIONS Transcranial gray-scale SHI using a low receiving frequency of 2.6 MHz is the superior method. PHI identifies contrast area localization better than gray-scale imaging and is particularly suitable for intraoperative and postoperative cases.
منابع مشابه
Second harmonic imaging: a new ultrasound technique to assess human brain tumour perfusion.
BACKGROUND Second harmonic imaging is a new ultrasound technique that allows evaluation of brain tissue perfusion after application of an ultrasound contrast agent. OBJECTIVE To evaluate the potential of this technique for the assessment of abnormal echo contrast characteristics of different brain tumours. METHODS 27 patients with brain tumours were studied. These were divided into four gro...
متن کاملContrast Improvement in Sub- and Ultraharmonic Ultrasound Contrast Imaging by Combining Several Hammerstein Models
Sub- and ultraharmonic (SUH) ultrasound contrast imaging is an alternative modality to the second harmonic imaging, since, in specific conditions it could produce high quality echographic images. This modality enables the contrast enhancement of echographic images by using SUH present in the contrast agent response but absent from the nonperfused tissue. For a better access to the components ge...
متن کامل[Automatic detection of perfusion deficits with Bolus Harmonic Imaging].
PURPOSE The diagnosis of ischemic stroke relies increasingly on the usage of ultrasound-based methods. One of the recent methods is the transcranial, contrast agent-based Bolus Harmonic Imaging (BHI) method. The captured image sequence is manually examined by clinical experts thus resulting in a time-consuming procedure. The purpose of this study is to evaluate three different methods to analyz...
متن کاملVisualization of brain perfusion with harmonic gray scale and power doppler technology : an animal pilot study.
BACKGROUND AND PURPOSE It is unclear which harmonic imaging mode (power Doppler or gray-scale imaging) is superior and which measuring method is the most robust for the description of brain perfusion. METHODS We performed an animal study on 6 beagles through the intact skull using a SONOS 5500 device and Optison injected intravenously in 3 different doses (0.15, 0.3, and 0.6 mL). Intensity ve...
متن کاملCARDIOVASCULAR MEDICINE Assessment of myocardial perfusion abnormalities by intravenous myocardial contrast echocardiography with harmonic power Doppler imaging: comparison with positron emission tomography
Background: Intravenous myocardial contrast echocardiography with harmonic power Doppler imaging (HPDI) enables assessment of myocardial perfusion. Its accuracy in comparison with positron emission tomography (PET), which is one of the most reliable clinical gold standards for myocardial perfusion, remains to be determined. Objective: To assess the ability of HPDI to identify myocardial perfusi...