Adsorptive voltammetry of 2-(5-bromo-2-pyridyl)azo-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol on a carbon paste electrode in the presence of organic cations and polycation.

نویسندگان

  • Toshiaki Hattori
  • Naoko Tsurumi
  • Ryo Kato
  • Masanori Nakayama
چکیده

The adsorption of ion-association complexes on a carbon paste electrode (CPE) was investigated by cyclic voltammetry using an electroactive hydrophobic anion probe. The redox reactions of 2-(5-bromo-2-pyridyl)azo-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol (5-Br-PAPS), the analytical probe, were irreversible. The reduction of the azo group and the oxidation of the phenol were observed at -0.1 V and 0.9 V vs. SCE, respectively, in a 0.1 mol L(-1) H(2)SO(4) solution. The peak currents for the redox reaction increased with the concentration of the cationic surfactant and the accumulation time. The increase in the ratio of the peak current to the concentration of cationic surfactants was proportional to the hydrophobicity. The peak current for 5-Br-PAPS also increased when a polycation, polyhexamethylene biguanide hydrochloride, was added and was strongly dependent on the ionic strength and pH, in contrast to cationic surfactants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Square-Wave Adsorptive Cathodic Stripping Voltammeteric Determination of Manganese (II) Using a Carbon Paste Electrode Modified with Montmorillonite Clay

Manganese is an essential micronutrient for all organisms; however at high concentrations it has a toxic effect. Manganese toxicity is a serious constraint to crop cultivation since it is taken-up by plants and can easily be passed into the food chain again causing symptoms of Parkinson’s disease. A fully validated square-wave adsorptive cathodic stripping voltammetry method has been developed ...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Cyclic flow-injection analysis for the repetitive determination of zinc with 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol and EDTA.

A circulatory flow-injection method (cyclic FIA) for the repetitive determination of zinc has been proposed. The procedure involves the use of 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol (5-Br-PAPS) together with EDTA as a reagent carrier solution, which is recycled in a single-line flow system via a reservoir. The formed 5-Br-PAPS-Zn(II) complex was measured spectropho...

متن کامل

Determination of Nicotinic Acid by Square Wave Voltammetry on a Carbon Paste Electrode: the Crucial Effect of Electrode Composition and Analytical Conditions

The foregone studies have shown that nicotinic acid cannot produce noticeable reductive signal at carbon-based electrodes without appropriate modification of the electrode. This is an obvious reason that mercury is known as the main electrode material for electro-reduction of nicotinic acid. In this study, it has been shown that it is possible to create a remarkable reduction signal for NA at a...

متن کامل

Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen

Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 12  شماره 

صفحات  -

تاریخ انتشار 2006