Estimating the probability that the Taser directly causes human ventricular fibrillation.
نویسندگان
چکیده
This paper describes the first methodology and results for estimating the order of probability for Tasers directly causing human ventricular fibrillation (VF). The probability of an X26 Taser causing human VF was estimated using: (1) current density near the human heart estimated by using 3D finite-element (FE) models; (2) prior data of the maximum dart-to-heart distances that caused VF in pigs; (3) minimum skin-to-heart distances measured in erect humans by echocardiography; and (4) dart landing distribution estimated from police reports. The estimated mean probability of human VF was 0.001 for data from a pig having a chest wall resected to the ribs and 0.000006 for data from a pig with no resection when inserting a blunt probe. The VF probability for a given dart location decreased with the dart-to-heart horizontal distance (radius) on the skin surface.
منابع مشابه
Can Tasers® directly cause ventricular fibrillation?
Tasers are battery powered electrical devices used by law enforcement personnel to temporarily incapacitate a suspect. This study is a portion of a larger study to determine the probability of a Taser (X26 and M26) causing ventricular fibrillation (VF) in humans. We determined the distance between a Taser dart and the ventricle (dart-to-heart distance) necessary to trigger VF in an in-vivo porc...
متن کاملCan the direct cardiac effects of the electric pulses generated by the TASER X26 cause immediate or delayed sudden cardiac arrest in normal adults?
There is only a small amount of experimental data about whether the TASER X26, a nonlethal weapon that delivers a series of brief electrical pulses to cause involuntary muscular contraction to temporarily incapacitate an individual, can initiate ventricular fibrillation to cause sudden cardiac arrest either immediately or sometime after its use. Therefore, this paper uses the fundamental law of...
متن کاملTaser-induced rapid ventricular myocardial capture demonstrated by pacemaker intracardiac electrograms.
INTRODUCTION A Taser weapon is designed to incapacitate violent individuals by causing temporary neuromuscular paralysis due to current application. We report the first case of a Taser application in a person with a dual-chamber pacemaker demonstrating evidence of Taser-induced myocardial capture. METHODS AND RESULTS Device interrogation was performed in a 53-year-old man with a dual-chamber ...
متن کاملLetter by Vilke et al regarding article, "sudden cardiac arrest and death following application of shocks from a TASER electronic control device".
BACKGROUND The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. METHODS AND RESULTS Eight cases of TASER X26 ECD-induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, ...
متن کاملModulation of extracellular atrioventricular node field potential pattern and ventricular rhythm by morphine in experimental atrial fibrillation in isolated rabbit heart
Introduction: Endorphins are produced by cardiomyocytes, and exert different effects on the heart. The aim of the present study is to assess morphine effects on extracellular atrioventricular (AV) node field potential pattern and ventricular rhythm of isolated rabbit heart during experimental atrial fibrillation (AF). Methods: Effects of different concentrations of morphine (10, 20, 50 and 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical engineering & technology
دوره 34 3 شماره
صفحات -
تاریخ انتشار 2010