Rapid three-dimensional echocardiography : clinically feasible alternative for precise and accurate measurement of left ventricular volumes.

نویسندگان

  • M Belohlavek
  • K Tanabe
  • D Jakrapanichakul
  • J F Breen
  • J B Seward
چکیده

BACKGROUND Clinical applicability of conventional ultrasonographic systems using mechanical adapters for 3D echocardiographic imaging has been limited by long acquisition and processing times. We developed a rapid (6-s) acquisition technique that collects apical tomograms using a continuously internally rotating transthoracic transducer. This study was performed to examine the clinical feasibility of rapid-acquisition 3D echocardiography to estimate left ventricular end-diastolic and end-systolic volumes using electron-beam computed tomography as the reference standard. Methods and Results-We collected a series of 6 to 11 apical echocardiographic tomograms, depending on heart rate, in 11 patients. There was good correlation, low variability, and low bias between rapid 3D echocardiography and electron-beam computed tomography for measuring left ventricular end-diastolic volume (r=0.96; standard error of the estimate, 21.34 mL; bias, -4.93 mL) and left ventricular end-systolic volume (r=0.96; standard error of the estimate, 14.78 mL; bias, -6.97 mL). CONCLUSIONS The rapid-acquisition 3D echocardiography extends the use of a multiplane, internally rotating handheld transducer so that it becomes a precise and clinically feasible tool for assessing left ventricular volumes and function. A rapid-image acquisition time of 6 s would allow repeated image collection during the course of a clinical echocardiographic examination. Additional work must address rapid and automated data processing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Assessment of Left Ventricular Volume and Function Using Real-Time 3D Echocardiography versus Angiocardiography in Children with Tetralogy of Fallot

BACKGROUND Evaluation of left ventricular (LV) size and function is one of the important reasons for performing echocardiography. Real time three dimensional echocardiography (RT3DE) is now available for a precise non-invasive ventricular volumetry. Aim of work was to validate RT3DE as a non-invasive cardiac imaging method for measurement of LV volumes using cardiac angiography as the reference...

متن کامل

Two-dimensional echocardiographic determination of ventricular volumes in the fetal heart. Validation studies in fetal lambs.

The determination of ventricular volumes in the fetal heart from two-dimensional echocardiography (2DE) may give a better estimate of fetal ventricular size than simple diameter measurements, but the accuracy of this method has not been established. In fetal lambs, we tested whether ventricular volume calculations from 2DE using a biplane Simpson's rule algorithm are accurate. Calculations of l...

متن کامل

Automated left heart chamber volumetric assessment using three-dimensional echocardiography in Chinese adolescents

BACKGROUND Several studies have reported the accuracy and reproducibility of HeartModel for automated determination of three-dimensional echocardiography (3DE)-derived left heart volumes and left ventricular (LV) ejection fraction (LVEF) in adult patients. However, it remains unclear whether this automated adaptive analytics algorithm, derived from a 'training' population, can encompass adequat...

متن کامل

Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function

BACKGROUND In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 103 24  شماره 

صفحات  -

تاریخ انتشار 2001