Numerical Calculations of Short-range Wakefields of Collimators
نویسندگان
چکیده
The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic structures. In this paper, numerical methods using codes such as MAFIA are used to determine a series of tapered collimators with rectangular apertures that have been built for studies at SLAC. We will study the dependences of the wakefield on the collimator taper angle, the collimator gap as well as the bunch length. Calculations are also compared with measurements.
منابع مشابه
Wakefield Calculations for 3 D Collimators ∗
Using a recently developed time domain numerical approach we calculate the short-range geometric wakefields of 3D collimators and compare with analytical models. We find, in the diffractive regime, that the transverse mode kick factor can be approximated from the change in field energy between the beam pipe and the collimator if the collimator is long, or using a “field clipping” estimate if it...
متن کاملTESLA Report 2003-18 NUMERICAL CALCULATION OF SMALL-ANGLE COLLIMATOR WAKEFIELDS FOR SHORT BUNCHES
Collimators are used to eliminate halo particles from the beam. To relax the wakefield effects a gradual transition from a large to a small aperture is used. However, the existing computer codes face severe problems for long tapered transitions. Two main sources of the problems are the grid dispersion and the staircase geometry approximation. Using recently developed time domain numerical appro...
متن کاملNumerical Calculation of Small-angle Collimator Wakefields for Short Bunches
Collimators are used to eliminate halo particles from the beam. To relax the wakefield effects a gradual transition from a large to a small aperture is used. However, the existing computer codes face severe problems for long tapered transitions. Two main sources of the problems are the grid dispersion and the staircase geometry approximation. Using recently developed time domain numerical appro...
متن کاملNear-wall Wakefields for Optimized Geometry of Ttf 2 Collimator
Wakefields excited in the small aperture collimators may damage the beam. As pointed out by K. Bane and P. Morton the wakefields can be reduced considerably by tapering the steps and using the “step+taper” collimator geometry. The optimisation of this kind of geometry for TTF 2 collimators with different apertures is carried out in the paper. For the optimal geometries the nonlinear near-wall w...
متن کاملCalculations of the Short-range Longitudinal Wakefields in the Nlc Linac
Using two frequency domain and one time domain numerical approaches, we calculate the short-range longitudinal wakefield of the NLC linac accelerating structure, and find that the results agree to 5%. We show that our results are consistent with an analytical formula for the impedance at high frequencies. We, in addition, obtain through fitting a simple formula for the short-range wakefield of ...
متن کامل