Ex vivo optical coherence tomography imaging of collector channels with a scanning endoscopic probe.
نویسندگان
چکیده
PURPOSE To achieve high-fidelity optical coherence tomography (OCT) imaging of ex vivo collector channels (CCs) exiting Schlemm's canal (SC) using a paired-angle rotating scanning endoscopic probe. METHODS An endoscopic probe was developed to guide an OCT laser beam onto human cadaver eye tissue samples to detect CCs. The prototype probe consisted of two gradient-index (GRIN) lenses that were housed in two stainless steel needles, respectively. The probe scanned the laser beam across a fan shape area by rotating the two GRIN lenses. The authors built a swept source OCT system to provide the depth scans. Human cadaver eye tissue was prepared for imaging. OCT images were acquired while the wall of SC was scanned. After successfully locating the opening of a CC on the SC wall from the OCT images, the authors applied scanning electron microscopy (SEM) to image the sample for comparison. RESULTS The prototype probe focused the laser beam to a working distance of approximately 1.4 mm (in air), with spot sizes ranging from 12 to 14 μm. The fan shape scan area had a radius of 3 mm and an arc angle of approximately 40°. Acquired OCT images clearly showed a CC opening on the wall of SC with the channel going into the sclera, from which quantitative measurements were made. Results from OCT and SEM show good agreement with each other. CONCLUSIONS The resolving power of the scanning endoscopic probe is sufficient to locate CCs and to observe their shape.
منابع مشابه
Piezoelectric-transducer-based miniature catheter for ultrahigh-speed endoscopic optical coherence tomography
We developed a piezoelectric-transducer- (PZT) based miniature catheter with an outer diameter of 3.5 mm for ultrahigh-speed endoscopic optical coherence tomography (OCT). A miniaturized PZT bender actuates a fiber and the beam is scanned through a GRIN lens and micro-prism to provide high-speed, side-viewing capability. The probe optics can be pulled back over a long distance to acquire three-...
متن کاملIn vivo and in situ cellular imaging full-field optical coherence tomography with a rigid endoscopic probe
Full-field OCT has proved to be a powerful high-resolution cellular imaging tool for biological tissues. However the standard bulk full-field OCT setup does not match the size requirements for most in situ and in vivo imaging applications. We adapted its principle into a rigid needle-like probe using two coupled interferometers and incoherent illumination: an external processing interferometer ...
متن کاملTrimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging.
In this Letter, we present a trimodality imaging system and an intravascular endoscopic probe for the detection of early-stage atherosclerotic plaques. The integrated system is able to acquire optical coherence tomography (OCT), fluorescence, and ultrasound images and simultaneously display them in real time. A trimodality intravascular endoscopic probe of 1.2 mm in diameter and 7 mm in length ...
متن کاملUltrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology
We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, whic...
متن کاملGRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking.
In this manuscript, a GRIN (gradient index) lens rod based probe for endoscopic spectral domain optical coherence tomography (OCT) with dynamic focus tracking is presented. Current endoscopic OCT systems have a fixed focal plane or working distance. In contrast, the focus of this endoscopic OCT probe can dynamically be adjusted at a high speed (500 mm/s) without changing reference arm length to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 7 شماره
صفحات -
تاریخ انتشار 2011