Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
نویسندگان
چکیده
PURPOSE Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The aim of this study was to analyze in a validated sawbone model with extended proximal femoral defects which types of implants have sufficient primary stability to allow osteointegration and to describe their fixation characteristics. METHODS Four different cementless megaprostheses were implanted into 16 Sawbones with an AAOS type III defect after resection 11 cm below the lesser trochanter involving the proximal isthmus. To determine the primary implant stability relative micromotions between bone and implant were measured in relation to a cyclic torque of 7Nm applied on the longitudinal axis of the implant. We determined the fixation characteristics of the different implant designs by comparing these relative micromotions along the longitudinal stem axis. RESULTS In the tested sawbones all studied implants showed sufficient primary stability to admit bone integration with relative micromotions below 150 µm after adapting our results to physiologic hip joint loadings. Different fixation characteristics of the megaprostheses were determined, which could be explained by their differing design and fixation concepts. CONCLUSIONS Cementless megaprostheses of different designs seem to provide sufficient primary stability to bridge proximal femoral defects if the diaphyseal isthmus is partially preserved. In our sawbone model the different implant fixation patterns can be related to their stem designs. No evidence can be provided to favor one of the studied implants in this setting. However, femoral morphology is variable and in different isthmus configurations specific implant designs might be appropriate to achieve the most favorable primary stability, which enables bone integration and consequently long term implant stability.
منابع مشابه
Autogenous Osteochondral Transplantation Mosaicplasty (An Animal Study on Sheep)
Background: Autogenous osteochondral grafting of articular defect in weight-bearing surface of large joints has proven to be a proper biomechanical and physiological solution for localized full-thickness defects.Objective: To study the gross and histopathological results of mosaicplasty in an animal model (sheep’s medial femoral condyle), evaluating the factors of defect and graft size, assessi...
متن کاملBiomechanical Evaluation of the Depth of Resection During Femoral Neck Osteoplasty for Anterior Impingement Following Slipped Capital Femoral Epiphysis.
BACKGROUND Femoroacetabular impingement as a result of slipped capital femoral epiphysis (SCFE) has been treated traditionally with a proximal femoral osteotomy, but open and arthroscopic femoral osteoplasty is becoming increasingly popular. Cam lesions result from excess bone primarily at the anterolateral femoral head-neck junction. SCFEs result from posterior and inferior slippage of the fem...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملOur experience of management of sub trochanteric fractures of femur by proximal femoral nail
The sub trochanteric zone of the femur is the area extending up till 5 cm distally from the inferior border of the lesser trochanter or the junction of the proximal third and middle third of the femoral shaft. Fracture patterns presenting major displacement in this area are considered sub trochanteric fractures despite their proximal or distal extension. 1 High biomechanical stress concentratio...
متن کاملPrecise Intra-operative Assessment of Rotation in Femoral Fracture Nailing
Background: A novel modification of an existing technique was developed to allow precise fluoroscopic assessment of rotational alignment of the fractured femur during intramedullary nailing. It is hypothesized that this will reduce the incidence of rotational malalignment which is reported to occur in 20-30 % of femoral fractures managed with intramedullary nails. The neck lateral technique has...
متن کامل