Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
نویسندگان
چکیده
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this study is to introduce a new configuration of miniscrew system which is believed to obtain more primary stability. MATERIAL AND METHODS Freshly ovine mandibles were cut in blocks. Twenty-seven miniscrews (diameter 1.6 × 8 mm; G2, Dual Top Anchor System, Jeil Medical, Seoul, Korea) were inserted in the blocks and divided in 2 experimental groups: single miniscrew and the innovated design "Seifi Twin Screw (STS)". Primary stability was evaluated by Periotest "M"® device. RESULTS Independent t-test showed a significant difference between 2 experimental groups in periotest evaluation (p< 0.05). STS demonstrated higher primary stability due to its mechanical configuration and design. CONCLUSIONS The STS provides higher primary stability and was found to be effective in increased success rate of miniscrew systems from the standpoint of primary stability. KEY WORDS Anchorage procedures, anchorage techniques, orthodontic anchorage procedures, miniscrews, temporary anchorage device.
منابع مشابه
Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملEffect of Pretreatment with Fluoride, Chlorhexidine, and Mixed Fluoride-Chlorhexidine Gels on Shear Bond Strength of Orthodontic Brackets: An Ex-Vivo Study
Background and Aim: Orthodontic patients are at an increased risk of caries due to difficulty in plaque control. Antimicrobial agents, such as fluoride and chlorhexidine, can be useful in preventing tooth demineralization. The present study aimed to determine the effect of fluoride and chlorhexidine gels and their mixture on the shear bond strength (SBS) of orthodontic brackets. Materials and ...
متن کاملPredictors of initial stability of orthodontic miniscrew implants.
The purpose of this retrospective study was to elucidate potential confounding factors affecting initial stability of miniscrews inserted to enhance orthodontic anchorage. Four hundred and seven miniscrews inserted in 168 patients treated by 17 orthodontic residents were analysed in a consecutive chart review. The outcome variable was the stability of the miniscrew, measured as a dichotomous va...
متن کاملIs the Palate an Optimal Site for Miniscrew Placement?
To test the hypothesis that palatal bone is able to support miniscrews when subjected to forces generatedduring orthodontic treatment. Finite element method software ANSYS10.0 was used. Tests were done in a state of osseointegration and non osseointegration. Two different palatal regions i.e. one layer of cortical bone and underlying trabecular bone; & two layers of cortical bone with trabecula...
متن کاملThe effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study.
The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability. In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil ...
متن کامل