Multifactorial design principles applied for the simultaneous separation of local anesthetics using chromatography modeling software
نویسنده
چکیده
This study describes the development of liquid chromatographic methods for the simultaneous separation of some of the most popular local anesthetics in pharmaceutical preparations and medical praxis (benzocaine, bupivacaine, chloroprocaine lidocaine, oxybuprocaine, prilocaine, procaine, propipocaine and tetracaine) based on a systematic approach using experimental design methodology in which one or more factors are changed at the same time. The strategy employs a chromatography modeling software for the simultaneous optimization of critical chromatographic parameters, which are gradient time tG, temperature T and the ternary composition of the organic eluent B. Three different stationary phases were investigated, which are: Kromasil C18, Prontosil C18-AQ and Luna Phenyl-Hexyl. To build the design space for each column, 12 initial experiments were carried out by systematical variation of the selected critical parameters simultaneously. The chromatographic conditions of these initial runs are based on two different gradient times (tG 1⁄4 20 and 60 min, linear gradient system from 10–90% organic modifier B) each at two different temperatures (T 1⁄4 25 and 40 C) repeated at three different ternary composition of the eluent B (a) 100% acetonitrile, (b) acetonitrile–methanol (50 : 50) (v/v), and (c) 100% methanol. In all experiments the pH value of the eluent A (20 mM phosphate buffer) was kept at 3.0. The mixture of local anesthetics could be well separated on all three stationary phases. Although not demonstrated in this paper, this method should be suitable for the analysis of LAs in pharmaceutical preparations or to detect them in some illegal cosmetics. The results showed that the selectivity and the elution order were similar on Kromasil C18 and Prontosil C18-AQ. On the other hand, a unique selectivity is resulted on Luna Phenyl-Hexyl, which shows, depending on the analytes, some additional interactions, since the separation mechanism on this column is influenced by its different steric and polar properties compared to the separation mechanism of alkyl-bonded phases. The predictions and real experiments were strongly correlated with an average absolute error (DtR) of 0.13 min (<8 s).
منابع مشابه
Applying evolutionary optimization on the airfoil design
In this paper, lift and drag coefficients were numerically investigated using NUMECA software in a set of 4-digit NACA airfoils. Two metamodels based on the evolved group method of data handling (GMDH) type neural networks were then obtained for modeling both lift coefficient (CL) and drag coefficient (CD) with respect to the geometrical design parameters. After using such obtained polynomial n...
متن کاملSimultaneous Determination of Preservatives (Sodium Benzoate and Potassium Sorbate) in Soft Drinks and Herbal Extracts Using High-Performance Liquid Chromatography (HPLC)
Background: Chemical preservation has become an increasingly important practice in modern food technology and herbal medicinal products with the increase in production of processed and convenience products. Objective: In the present study, a reversed-phased HPLC method for simultaneous determination of the preservatives sodium benzoate (SB) and potassium sorbate (PS) is described. Methods: Th...
متن کاملSimultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography
Background and objectives: High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materi...
متن کاملSimultaneous Allocation Of Reliability & Redundancy Using Minimum Total Cost Of Ownership Approach
This paper addresses the mixed integer reliability redundancy allocation problems to determine simultaneous allocation of optimal reliability and redundancy level of components based on three objective goals. System engineering principles suggest that the best design is the design that maximizes the system operational effectiveness and at the same time minimizes the total cost of ownership (TCO...
متن کاملPhysical separation of amphiprotic-polar aprotic solvents for simultaneous extraction and clean-up of clomiphene from plasma before liquid chromatographic analyzes
An efficient and quantitative two phase freezing (TPF) method coupled with high performance liquid chromatography and UV-Vis detector was developed for the extraction, clean up and determination of clomiphene citrate (CLC) in plasma samples. The separation of two miscible solvents by TPF method permits that the CLC was efficiently removed from proteins and transferred into the relative aprotic ...
متن کامل