A comparative evaluation of pulmonary artery balloon counterpulsation and a centrifugal flow pump in an experimental model of right ventricular infarction.

نویسندگان

  • A J Taylor
  • F H Edwards
  • M G Macon
  • B Worley
  • G M Graeber
چکیده

To compare the efficiency of pulmonary artery balloon counterpulsation and a centrifugal flow pump in reversing the hemodynamic consequences of acute right-sided heart failure, we employed both devices in 14 Yorkshire pigs in which right ventricular infarction was created via surgical ligation of branches of the right coronary artery. Pulmonary artery balloon counterpulsation improved some of the indicators of right heart failure, as manifested by significantly decreased right atrial pressure and increased mean systemic blood pressure. In contrast, the centrifugal flow pump consistently and significantly reversed all of the hemodynamic consequences of right ventricular infarction. In comparison to pulmonary artery balloon counterpulsation, the centrifugal flow pump resulted in lower right atrial pressures (p=0.020), lower mean pulmonary pressures (p less than 0.0001), increased left atrial pressures (p=0.026), increased cardiac output (p less than 0.0001), and increased mean systemic blood pressures (p less than 0.0001). Possible mechanisms to explain the superiority of the centrifugal flow pump include better hemodynamic unloading of the failing myocardium and independence from right ventricular output.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

A Review of the Literature on Pulmonary Artery Balloon Counterpulsation and a Successful Application of Concomitant Balloon Counterpulsation

____________ _ The intraaortic balloon pump is the most common method of left ventricular support in use today. Various types of ventricular assist devices and centrifugal pumps are also used at many institutions for both single and biventricular support. Balloon pump technology can also be used to support the right ventricle, as we were able to recently demonstrate in a successful application ...

متن کامل

Aggressive management of acute myocardial infarction: successful outcome in an older patient with cardiogenic shock.

A 71-year-old man was referred to our emergency department presenting with acute inferior and right ventricular myocardial infarction with cardiogenic shock. He developed ventricular fibrillation 80 minutes after arrival. Immediate defibrillation, mechanical ventilatory support with oxygenation, and inotropic agents were instituted. Despite restoration of sinus rhythm, his hypotension persisted...

متن کامل

Systematic review: Intra-aortic balloon counterpulsation pump therapy: a critical appraisal of the evidence for patients with acute myocardial infarction

Introduction Intra-aortic balloon counterpulsation pump (IABP) therapy has been used in several clinical situations, predominantly in critically ill patients, since 1968 [1]. In acute myocardial infarction (AMI) patients who are experiencing continued ischemia, IABP therapy may be used in an attempt to improve patency of an infarct-related coronary artery (IRA) and reduce the rates of recurrent...

متن کامل

Myocardial free-wall rupture after acute infarction: survival aided by percutaneous intraaortic balloon counterpulsation.

After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1990