Determining iron without copper interference from carryover of total protein reagent in Hitachi analyzers.

نویسندگان

  • A J Bakker
  • R Lerk
  • B Reitsma
  • F Reitsma
  • V de Vrij
چکیده

Hitachi704 Unmodified No 155 y 1.OOlx + 0.23 0.988 0.0118 0.225 0.29 Unmodified Yes 52 y = 1.059x + 9.71 0.987 0.0234 0.453 10.71 b Modified Yes 155 y = 1.047x 0.50 0.996 0.0074 0.142 0.21 Hitachi 717 Unmodified No 155 y = 1.025x + 0.14 0.977 0.0213 0.425 0.57 Unmodified Yes 31 y = 1.040x + 3.20 0.960 0.0522 1.283 406b Modified Yes 155 y = 1.065x 0.19 0.983 0.01 89 0.380 Three sets of samples were analyzed for iron and their resultscompared:samples withnocopper reagent carryover, samples with copper reagent carryover, and samples with copper reagent carryoverbut withmodified iron assay reagent. bornerencesignificant at P <0.001. Sb Mean dill., imol/L Table 1. ClinIcal and Biological Data for Tumor Patients and Normal Subjects

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved direct specific determination of serum iron and total iron-binding capacity.

Serum iron is released from transferrin and reduced at pH 1.7 by treating serum with a 10 g/L ascorbic acid solution in 0.1 mol/L HCl. When ferrozine is added to this reagent, it forms a complex with iron that is as intensely colored as at higher pH values, and under these conditions no turbidity is produced. The second major interference, that from copper, is eliminated by adding 1 g of thiose...

متن کامل

A multi-factor experimental design for evaluating random-access analyzers.

A multi-factor experimental design for evaluating random-access analyzers has been developed and tested for the Ciba Corning "550 Express" random-access analyzer. The 12-sample design estimates imprecision, slope, nonlinearity, linear drift, and reagent carryover to the next assay. The design was constructed so that estimates of the factors' effects are almost entirely uninfluenced by each othe...

متن کامل

Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.

We evaluated the effect of hemolysis, icteric discoloration, lipemia, paraproteinemia, and uremia on enzymatic methods for determining sodium, potassium, and chloride, according to the National Committee for Clinical Laboratory Standards EP7-P proposals for testing interference from endogenous substances. The sodium, potassium, and chloride assays (reagent kits supplied by Boehringer Mannheim) ...

متن کامل

Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests.

Polymerized hemoglobin solutions (Hb-based oxygen carriers; HBOCs) and a second-generation perfluorocarbon (PFC) emulsion (Perflubron) are in clinical trials as temporary oxygen carriers ("blood substitutes"). Plasma and serum samples from patients receiving HBOCs look markedly red, whereas those from patients receiving PFC appear to be lipemic. Because hemolysis and lipemia are well-known inte...

متن کامل

Performance and Nutrient Utilization of Broilers Supplemented Mineral Premix without Cobalt, Iron and Copper

Ninety, day old broiler chicks were arranged into 5X3X6 pattern to investigate the effect of exclusion of Cobalt, Iron and Copper from the mineral mixture. Five dietary groups (T1 to T5) were assigned basal diets containing 2800 kcal ME/kg and 22% CP (Starter) and 20% (Finisher) for a total duration of 6 weeks. The chicks in T1 were fed commercial mineral mixture, T2 were supplemented with mine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 11  شماره 

صفحات  -

تاریخ انتشار 1988