Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus.
نویسندگان
چکیده
Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compared with the conventional slide coagulase, tube coagulase (TC), and thermonuclease (TNase) tests for the identification of Staphylococcus aureus. A total of 118 clinical isolates of S. aureus (52 methicillin resistant), 50 S. epidermidis, 5 S. capitis, 2 S. hominis, 3 S. simulans, 6 S. saprophyticus, and 2 S. warneri were tested. The slide coagulase, TC and TNase tests detected 115 (97.5%), 117 (99.2%), and 118 (100%) of the S. aureus isolates, respectively. All showed 100% specificity. The StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph assays correctly identified 117 (99.2%), 117 (99.2%), 116 (98.3%), 110 (93.2%), 108 (91.5%), and 107 (90.7%) of the S. aureus isolates, respectively. For methicillin-resistant S. aureus isolates, StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph showed 1 (2%), 1 (2%), 2 (4%), 7 (13.5%), 7 (13.5%), and 8 (15.4%) false-negative results, respectively. All the commercial agglutination assays demonstrated false-positive results with strains of S. capitis, S. saprophyticus and S. warneri. The overall accuracy of the commercial agglutination assays compared with TC and TNase ranged from 90.7 to 99.2%. We recommend that negative reactions with the rapid commercial test kits for methicillin-resistant Staphylococcus isolates be confirmed with the TC or TNase test.
منابع مشابه
Bacterial Mastitis in Lactating Women Attending Mirzakochackkhan Hospital during 2003-2004 and the Sensitivity Pattern of the Involved Bacteria
Introduction: Mastitis is an inflammatory condition of the breast and since it is usually associated with lactation , it is usually called lactational mastitis. Two major causes of mastitis are milk stasis and infection. The aim of this study was to evaluate bacterial mastitis in lactating women and to determine the sensitivity pattern of the involved bacteria. Method: A total of 203 milk sampl...
متن کاملMolecular Identification and Antibacterial Drug Resistance Pattern of Staphylococcus Aureus Isolated in Rasht, Iran
Abstract Background and Objective: Staphylococcus aureus is an important opportunistic pathogen causing a wide range of infections in human .Most clinical isolates of S.aureus are resistant to a number of antibiotics. For appropriate antimicrobial therapy, this study was conducted to determine antibacterial drug resistance patterns of S.aureus isolates obtained from different clinical samp...
متن کاملBacterial Mastitis in Lactating Women Attending Mirzakochackkhan Hospital during 2003-2004 and the Sensitivity Pattern of the Involved Bacteria
Introduction: Mastitis is an inflammatory condition of the breast and since it is usually associated with lactation , it is usually called lactational mastitis. Two major causes of mastitis are milk stasis and infection. The aim of this study was to evaluate bacterial mastitis in lactating women and to determine the sensitivity pattern of the involved bacteria. Method: A total of 203 milk sampl...
متن کاملEvaluation of three rapid methods for the direct identification of Staphylococcus aureus from positive blood cultures.
Staphylococci represent the most commonly encountered blood culture isolates. Differentiating Staphylococcus aureus from coagulase-negative staphylococci (CoNS) is important in guiding empirical therapy, especially since the majority of CoNS are contaminants. This study evaluated three rapid methods for the direct identification of S. aureus from blood cultures. A total of 157 patient blood cul...
متن کاملEvaluation of various rapid agglutination methods for the identification of Staphylococcus aureus.
A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 23 5 شماره
صفحات -
تاریخ انتشار 1986