Cerebral tissue oxygen saturation calculated using low frequency haemoglobin oscillations measured by near infrared spectroscopy in adult ventilated patients.
نویسندگان
چکیده
Oxy- (HbO2) and deoxy- (HHb) haemoglobin signals measured by near infrared (NIR) spectroscopy over the human frontal lobes frequently contain respiratory and low frequency oscillations (LFOs). It has been suggested previously that venous oxygen saturation (SvO2) can be calculated from these respiratory oscillations. In this paper, we investigated the use of a Fourier transform based algorithm to calculate an oxygen saturation measure known as S(osc)O2 which may be a close estimate of the underlying SvO2. S(osc)O2 was calculated using three different frequency ranges, (1) respiratory oscillations only, (2) LFOs only, and (3) both respiratory oscillations and LFOs. At each frequency range S(osc)O2 was calculated using either (1) the modified Beer-Lambert law (MBL) or (2) spatially resolved spectroscopy (SRS). In total six different measurements of S(osc)O2 were investigated here. Experiments were performed in six adult ventilated patients with traumatic brain injury. The patients' inspired oxygen fraction (FiO2) was raised in two hyperoxic phases. The calculated S(osc)O2 values were compared with other cerebral oxygenation measures including an intraparenchymal catheter based brain tissue oxygen tension (PbrO2) and the NIR based tissue oxygenation index (TOI). It was found that the S(osc)O2 calculated using the combined respiratory and LFO frequency range and the SRS method resulted in the highest detection rates of hyperoxic changes. This measure of S(osc)O2 may provide a viable, continuous, non invasive, bedside measure of cerebral venous oxygen saturation.
منابع مشابه
Quantification of adult cerebral blood volume using the NIRS tissue oxygenation index.
Near-infrared spectroscopy (NIRS) is increasingly used as a non-invasive technique for monitoring cerebral oxygenation and haemodynamics . Simple continuous-wave (CW) NIRS systems utilising differential spectroscopy can measure quantitative changes in oxyand deoxyhaemoglobin (∆[O2Hb], ∆[HHb]) but only from an arbitrary baseline. Numerous studies of changes in cerebral oxygenation and haemodynam...
متن کاملSome factors affecting cerebral tissue saturation during obstructive sleep apnoea.
Measurement of cerebral tissue saturation during obstructive sleep apnoea (OSA) may provide additional information to conventional peripheral oxygen saturation. Thirteen subjects with OSA (mean apnoea/hypopnoea index 65.7+/-27.9) were monitored using full polysomnography and monitoring of near-infrared cerebral tissue oxygenation index (TOI). One-thousand and thirty-six apnoeas and hypopnoeas w...
متن کاملCorrelation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کاملSpectral characteristics of spontaneous oscillations in cerebral haemodynamics are posture dependent.
Autonomic reflexes are responsible for adjusting the cardiovascular system in response to gravitational displacement of blood during changes in posture. In human physiology, a posture change from supine to standing results in venous pooling in the lower limbs and pelvic area (equivalent to the loss of 500ml of blood from the systemic circulation) and an increased filtration from capillaries int...
متن کاملStudy protocol for the PHANTOM study: prehospital assessment of noninvasive tissue oximetry monitoring
BACKGROUND Traumatic brain injury is a major cause of mortality and morbidity worldwide. It can be worsened by secondary injury particularly with hypoxia or hypotension. Current prehospital guidelines emphasise regular measurement of peripheral oxygen saturation and blood pressure but there is no monitor in use to provide direct information relating to blood flow or oxygen delivery to the brain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Advances in experimental medicine and biology
دوره 614 شماره
صفحات -
تاریخ انتشار 2008