Validity of hip-mounted uniaxial accelerometry with heart-rate monitoring vs. triaxial accelerometry in the assessment of free-living energy expenditure in young children: the IDEFICS Validation Study.

نویسندگان

  • Robert Ojiambo
  • Kenn Konstabel
  • Toomas Veidebaum
  • John Reilly
  • Vera Verbestel
  • Inge Huybrechts
  • Isabelle Sioen
  • José A Casajús
  • Luis A Moreno
  • German Vicente-Rodriguez
  • Karin Bammann
  • Bojan M Tubic
  • Staffan Marild
  • Klaas Westerterp
  • Yannis P Pitsiladis
چکیده

One of the aims of Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants (IDEFICS) validation study is to validate field measures of physical activity (PA) and energy expenditure (EE) in young children. This study compared the validity of uniaxial accelerometry with heart-rate (HR) monitoring vs. triaxial accelerometry against doubly labeled water (DLW) criterion method for assessment of free-living EE in young children. Forty-nine European children (25 female, 24 male) aged 4-10 yr (mean age: 6.9 ± 1.5 yr) were assessed by uniaxial ActiTrainer with HR, uniaxial 3DNX, and triaxial 3DNX accelerometry. Total energy expenditure (TEE) was estimated using DLW over a 1-wk period. The longitudinal axis of both devices and triaxial 3DNX counts per minute (CPM) were significantly (P < 0.05) associated with physical activity level (PAL; r = 0.51 ActiTrainer, r = 0.49 uniaxial-3DNX, and r = 0.42 triaxial Σ3DNX). Eight-six percent of the variance in TEE could be predicted by a model combining body mass (partial r(2) = 71%; P < 0.05), CPM-ActiTrainer (partial r(2) = 11%; P < 0.05), and difference between HR at moderate and sedentary activities (ModHR - SedHR) (partial r(2) = 4%; P < 0.05). The SE of TEE estimate for ActiTrainer and 3DNX models ranged from 0.44 to 0.74 MJ/days or ∼7-11% of the average TEE. The SE of activity-induced energy expenditure (AEE) model estimates ranged from 0.38 to 0.57 MJ/day or 24-26% of the average AEE. It is concluded that the comparative validity of hip-mounted uniaxial and triaxial accelerometers for assessing PA and EE is similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children's activities.

Heart rate telemetry is frequently used to estimate daily activity in children and to validate other methods. This study compared the accuracy of heart rate monitoring, pedometry, triaxial accelerometry, and uniaxial accelerometry for estimating oxygen consumption during typical children's activities. Thirty Welsh children (mean age 9.2 +/- 0.8 yr) walked (4 and 6 km/h) and ran (8 and 10 km/h) ...

متن کامل

Review of Prediction Models to Estimate Activity-Related Energy Expenditure in Children and Adolescents

Purpose. To critically review the validity of accelerometry-based prediction models to estimate activity energy expenditure (AEE) in children and adolescents. Methods. The CINAHL, EMBASE, PsycINFO, and PubMed/MEDLINE databases were searched. Inclusion criteria were development or validation of an accelerometer-based prediction model for the estimation of AEE in healthy children or adolescents (...

متن کامل

Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study

BACKGROUND Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels a...

متن کامل

Comparison of the TriTrac-R3D accelerometer and a self-report activity diary with heart-rate monitoring for the assessment of energy expenditure in children.

Determining total energy expenditure (EE) in children under free-living conditions has become of increasingly clinical interest. The aim of this study was to compare three different methods to assess EE triaxial accelerometry (TriTrac-R3D; Professional Products, Division of Reining International, Madison, WI, USA), activity diary and heart-rate (HR) monitoring combined with indirect calorimetry...

متن کامل

Validity of combining heart rate and uniaxial acceleration to measure free-living physical activity energy expenditure in young men.

Combining accelerometry (ACC) with heart rate (HR) monitoring is thought to improve activity energy expenditure (AEE) estimations compared with ACC alone to evaluate the validity of ACC and HR used alone or combined. The purpose of this study was to estimate AEE in free-living conditions compared with doubly labeled water (DLW). Ten-day free-living AEE was measured by a DLW protocol in 35 18- t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 113 10  شماره 

صفحات  -