Chip electrophoresis as a method for quantifying total microalbuminuria.
نویسندگان
چکیده
BACKGROUND Microalbuminuria is an important prognostic marker in diabetic nephropathy and cardiovascular disease. Initially, most commercial assays used immunoreactivity to quantify microalbuminuria; however, size-exclusion HPLC demonstrated the existence of nonimmunoreactive forms of albumin that may not be detected by immunoassay. Recent liquid chromatography tandem mass spectrometry analyses suggested that size-exclusion HPLC gave higher results attributable to other urine proteins coeluting with albumin. We describe an assay that measures total microalbuminuria (immunoreactive and nonimmunoreactive) without any discernable interference from other common urine proteins. METHODS We used an automated chip electrophoresis system that utilized microfluidic separation technology and fluorescent sample detection. Each albumin specimen was mixed with the manufacturer's sample buffer in addition to a chicken albumin internal calibrator and then electrophoresed without additional reducing agents. RESULTS With variable concentrations of bovine serum albumin normalized to a chicken albumin internal calibrator, the electrophoresis system was best fit with a polynomial (R2=0.9997; concentration range, 5-300 mg/L). The lower limit of detection was 5 mg/L. Interchip and intrachip variation studies conducted on patient urine demonstrated CVs of 3%-13%. The introduction of potentially interfering agents (i.e., molecular analytes, nonalbumin proteins) did not alter precision. Compared with immunoassay, the chip electrophoresis identified higher microalbuminuria concentrations in all urine samples. The method also clearly resolved the albumin peak from interfering proteins. CONCLUSIONS Unlike immunoassay, chip electrophoresis can detect both immunoreactive and nonimmunoreactive forms of albumin. This system is a simple, robust method to quantify microalbuminuria with good sensitivity, precision, and accuracy.
منابع مشابه
Measurement of microalbuminuria using protein chip electrophoresis.
Microalbuminuria reflects the progression of nephropathy and cardiovascular disease in diabetic and hypertensive patients. Most commercially available tests currently used to measure microalbuminuria are immunoassays. We developed a microfluidics-based assay using the P200 protein chip (Caliper Life Sciences, Mountain View, CA, and Agilent Technologies, Santa Clara, CA) and 2100 Bioanalyzer (Ag...
متن کاملComparison of Two Spectrophotometric Methods for Quantifying Total Hydroxycinnamic Acids in Coneflower (Echinacea purpurea) Preparations
Background & Aim: Hydroxycinnamic acids are one of the most important bioactive substances of Echinacea drugs. These compounds possess immuno-enhancing activity and thus, total hydroxycinnamic acids are mostly used as the main criterion for quality control of Echinacea purpurea and its drugs. Hence, the quality control of Echinacea requires to develo...
متن کاملComparison of Two Spectrophotometric Methods for Quantifying Total Hydroxycinnamic Acids in Coneflower (Echinacea purpurea) Preparations
Background & Aim: Hydroxycinnamic acids are one of the most important bioactive substances of Echinacea drugs. These compounds possess immuno-enhancing activity and thus, total hydroxycinnamic acids are mostly used as the main criterion for quality control of Echinacea purpurea and its drugs. Hence, the quality control of Echinacea requires to develo...
متن کاملارزیابی روشهای الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری
Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...
متن کاملA rapid standardized quantitative microfluidic system approach for evaluating human tear proteins
PURPOSE To explore the potential of a chip-based miniaturized capillary gel electrophoresis device in a quantitative evaluation of the human tear protein profile and to validate the method. METHODS A total of 5 μl of tears were collected from 25 patients diagnosed as having mild to moderate dry eye according to Dry Eye Workshop guidelines and from 20 matched normal volunteers. Protein analysi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 52 11 شماره
صفحات -
تاریخ انتشار 2006