An in vitro pilot study of the abutment stability during loading in virgin and fatigue-loaded conical dental implants using synchrotron-based radiography
نویسندگان
چکیده
The implant-abutment connection of a two-piece dental implant depicts a complex micro-mechanical behavior: a micro-gap is evident at the implant-abutment interface, even in the virgin state. Its width varies when external mechanical load is applied. High resolution synchrotron-based radiography in combination with hard X-ray phase contrast to image this gap and estimate its size is deployed. The study involves commercially available implants with different internal conical implant-abutment connections. A comparison between virgin implants and the fatigue loaded implants underlines that fatigue extends the size of the micro-gap and increases the ability of micromovement. The cone angle of the connection influences the stability of the abutment. Cyclic loading at medium force (120 N) hence induces plastic deformation of the titanium implant.
منابع مشابه
In vitro synchrotron-based radiography of micro-gap formation at the implant–abutment interface of two-piece dental implants
Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as wel...
متن کاملValidation of finite-element simulations with synchrotron radiography – A descriptive study of micromechanics in two-piece dental implants
State-of-the art, two-piece dental implants made from titanium alloys exhibit a complex micromechanical behavior under dynamical load. Its understanding, especially the formation of microgaps, is of crucial importance in order to predict and improve the long-term performance of such implants. Microgap formation in a loaded dental implant with a conical implant-abutment connection can be studied...
متن کاملEvaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study
Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...
متن کاملIn situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants
Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant-abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next st...
متن کاملImmediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کامل