Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of intraocular pressure.

نویسندگان

  • Anna I Dastiridou
  • Harilaos S Ginis
  • Dirk De Brouwere
  • Miltiadis K Tsilimbaris
  • Ioannis G Pallikaris
چکیده

PURPOSE The purpose of this study was to characterize the pressure-volume relation in the living human eye, measure the ocular pulse amplitude (OPA), and calculate the corresponding pulsatile ocular blood flow (POBF) in a range of clinically relevant IOP levels. METHODS Fifty patients with cataract (50 eyes) were enrolled in the study. After cannulation of the anterior chamber, a computer-controlled device for the intraoperative measurement and control of IOP was used to artificially increase the IOP in a stepping procedure from 15 to 40 mm Hg. The IOP was continuously recorded for 2 seconds after each infusion step. The pressure-volume relation was approximated with an exponential fit, and the ocular rigidity coefficient was computed. OPA, pulse volume (PV), and POBF were measured from the continuous IOP recordings. RESULTS The average rigidity coefficient was 0.0224 microL(-1) (SD 0.0049). OPA increased by 91% and PV and POBF decreased by 29% and 30%, respectively, when increasing the IOP from 15 to 40 mm Hg. The OPA is positively correlated with the coefficient of ocular rigidity (r = 0.65, P < 0.01). CONCLUSIONS The present results suggest a nonlinear pressure-volume relation in the living human eye characterized by an increase in rigidity at higher IOP levels. The increased OPA and decreased pulse volume relate to the decreased POBF and the increased mechanical resistance of the ocular wall at high IOP levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of sex difference in measurements with the Langham Ocular Blood Flow System.

PURPOSE To assess sex difference and parameters possibly accounting for such a difference in healthy subjects evaluated by means of the Langham Ocular Blood Flow (OBF) System. METHODS Pulse amplitude of intraocular pressure (IOP) and pulsatile ocular blood flow (POBF) as measured with the Langham OBF System were assessed in 86 healthy men and 69 healthy women. RESULTS Compared to men, women...

متن کامل

Postural studies in pulsatile ocular blood flow: II. Chronic open angle glaucoma.

The pulsatile ocular blood flow (POBF) has been recorded in 15 patients with chronic open angle glaucoma. Measurements were performed during regular treatment with timolol 0.25% eyedrops, two weeks after withdrawal of this treatment, and then a further two weeks after its reinstitution. Readings were taken with subjects in both the erect and supine positions by means of a pneumotonometric probe...

متن کامل

Estimation of ocular rigidity based on measurement of pulse amplitude using pneumotonometry and fundus pulse using laser interferometry in glaucoma.

PURPOSE There is evidence from theoretical models and animal studies that the biomechanical properties of the optic nerve head and the sclera play a role in the pathophysiology of glaucoma. There are, however, only a few data available that demonstrate such biomechanical alterations in vivo. In this study, the hypothesis was that patients with primary open-angle glaucoma (POAG) have an abnormal...

متن کامل

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

Review on Dynamic Contour Tonometry and Ocular Pulse Amplitude.

Intraocular pressure (IOP) measurement is the cornerstone of the management of glaucoma patients. The gold standard for assessing IOP is Goldmann applanation tonometry (GAT). Recently, the dynamic contour tonometer (DCT) has become available. While both devices provide reliable IOP measurements, the results are not interchangeable. DCT has the advantage of measuring an additional parameter: ocu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2009