Changes in Basal Insulin Infusion Rates With Subcutaneous Insulin Infusion
نویسندگان
چکیده
OBJECTIVE Evaluation of the time required until a change in the basal insulin infusion rate with an insulin pump induces subsequent changes in the metabolic effect. RESEARCH DESIGN AND METHODS In this euglycemic glucose clamp study, 10 male subjects with type 1 diabetes received three different subcutaneous insulin infusion rates (0.5, 1.0, and 2.0 units/h; for 4 h each) of insulin lispro (IL) with insulin pumps. RESULTS An increase in insulinemia occurred within 15-30 min after changing the infusion rate. While the serum IL levels reached a steady state at the end of the infusion period, the glucose infusion rates did not always reach steady-state levels with the higher infusion rates. However, an increase in the glucose consumption occurred within 30-60 min after switching the infusion rate. CONCLUSIONS Several hours are required until a new steady state in the metabolic effect is achieved after a significant change in basal insulin infusion.
منابع مشابه
Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)
OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...
متن کاملClassification of distinct baseline insulin infusion patterns in children and adolescents with type 1 diabetes on continuous subcutaneous insulin infusion therapy.
OBJECTIVE We hypothesized systematic differences in the patterns of programmed basal insulin infusion rates in children and adolescents with type 1 diabetes on continuous subcutaneous insulin infusion (CSII). We aimed at classification of basal insulin infusion rate regimens and comparing patients' underlying clinical characteristics. RESEARCH DESIGN AND METHODS The German/Austrian diabetes d...
متن کاملExplorative study of pharmacokinetics and pharmacodynamics after change in basal insulin infusion rate.
BACKGROUND The use of insulin pumps is rapidly increasing and new, technologically more advanced pumps are continuously being developed. It is of interest to assess the clinical relevance of the many technical features of these pumps, e.g., the effect on pharmacokinetics and pharmacodynamics with change in infusion rate. METHOD The aim of this study was to explore the sequence of pharmacokine...
متن کاملSiphon effects on continuous subcutaneous insulin infusion pump delivery performance.
BACKGROUND The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. METHODS We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instruct...
متن کاملSafety of insulin glulisine when given by continuous subcutaneous infusion using an external pump in patients with type 1 diabetes.
This twelve-week, European, multicenter, controlled, open-label, randomized (1 : 1), parallel-group trial compared the safety of insulin glulisine with insulin as part used in continuous subcutaneous insulin infusion. Patients with type 1 diabetes (n=59) and continuous subcutaneous insulin infusion experience (mean values: HbA1c 6.9 % [insulin glulisine: 6.8 % VS. insulin as part: 7.1 %]; age 4...
متن کامل