The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation.

نویسندگان

  • G W Maier
  • G S Tyson
  • C O Olsen
  • K H Kernstein
  • J W Davis
  • E H Conn
  • D C Sabiston
  • J S Rankin
چکیده

In intact chronically instrumented dogs, left ventricular dynamics were studied during cardiopulmonary resuscitation (CPR). Electromagnetic flow probes measured cardiac output and coronary blood flow, ultrasonic transducers measured cardiac dimensions, and micromanometers measured left ventricular, right ventricular, aortic, and intrathoracic pressures. The dogs were anesthetized with morphine, intubated, and fibrillated by rapid ventricular pacing. Data were obtained during manual external massage with dogs in the lateral and supine positions. Force of compression was varied from a peak intrathoracic pressure of 10 to 30 mm Hg, and compression rate was varied from 60 to 150/min. Increasing force of compression increased stroke volume up to a peak intrathoracic pressure of approximately 20 mm Hg, beyond which stroke volume remained constant or declined. Stroke volume appeared to result primarily from direct transmission of manual compression force to the heart rather than from positive intrathoracic pressure because peak cardiac or vascular pressures or the change in these pressures were consistently two to four times greater than the corresponding intrathoracic pressures during manual compression. With increasing compression rate, stroke volume remained relatively constant, and total cardiac output increased significantly: 425 +/- 92 ml/min at 60/min, 643 +/- 130 ml/min at 100/min, and 975 +/- 219 ml/min at 150/min (p less than .05). Left ventricular dimensions decreased minimally at higher manual compression rates. In four patients undergoing CPR, systolic and diastolic arterial blood pressure increased with faster compression rates, correlating well with data obtained in the dog. Dynamic coronary blood flow in canine experiments decreased to zero or negative values during compression. Antegrade coronary flow occurred primarily during noncompression periods and seemed to be related to diastolic aortic perfusion pressure; coronary flow at a compression rate of 150/min averaged 75% of control. Therefore stroke volume and coronary blood flow in this canine preparation were maximized with manual chest compression performed with moderate force and brief duration. Increasing rate of compression increased total cardiac output while coronary blood flow was well maintained. Direct cardiac compression appeared to be the major determinant of stroke volume during manual external cardiac massage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic diameter and pressure-flow sequence identify mechanism of blood flow during external chest compression in dogs.

Aortic flow and pressure relations and aortic diameter were examined during sinus rhythm, internal cardiac massage, vest cardiopulmonary resuscitation, conventional manual cardiopulmonary resuscitation and high impulse manual cardiopulmonary resuscitation in 14 anesthetized large dogs. During sinus rhythm and during internal cardiac massage, ascending aortic flow and pressure increased simultan...

متن کامل

Traumatic Tricuspid Regurgitation Following Cardiac Massage

We report a 66-yr-old male patient who developed tricuspid regurgitation secondary to internal cardiac massage. After uneventful off-pump coronary artery bypass surgery, the subject experienced cardiac arrest in the intensive care unit. External cardiac massage was initiated and internal cardiac massage was performed eventually. A transesophageal echocardiography revealed avulsion of the anteri...

متن کامل

Quality of the cardiac massage provided by special Nurses in Birjand’s hospitals, Birjand, Iran during 2019: Short Communication

The prognosis of patients with cardiac arrest depends on the provision of high quality cardiac massage and the nurses are expected to be able to provide high-quality cardiac massage. Therefore, this study aimed to investigate the quality of cardiac massage and its effective factors in 90 nurses of Birjand hospitals, Birjand, Iran, in 2019. This cross-sectional descriptive study was conducted us...

متن کامل

Chest compression rate: where is the sweet spot?

The first description of modern cardiopulmonary resuscitation (CPR) included the instruction to compress the chest “about 60 times per minute”1; however, the optimal compression rate was unknown. Franz Koenig is credited with describing the original technique for external cardiac massage, which included a compression rate of 30 to 40 per minute.2 But in the first published description of extern...

متن کامل

Chest Compression Rate Where Is the Sweet Spot ? Jerry

The first description of modern cardiopulmonary resuscitation (CPR) included the instruction to compress the chest “about 60 times per minute”1; however, the optimal compression rate was unknown. Franz Koenig is credited with describing the original technique for external cardiac massage, which included a compression rate of 30 to 40 per minute.2 But in the first published description of extern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 1984