Passive removal of silicone oil through 23 gauge transconjunctival sutureless vitrectomy system

نویسندگان

  • Nisar Ahmed Siyal
  • Lakhani Das Hargun
  • Shahid Wahab
چکیده

OBJECTIVE To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System. METHODS This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Main outcome measures were intra ocular pressure, time taken for removal of silicone oil, per operative and post operative complications. Pre and post operative IOP was compared by using two-tailed paired t-test and mean values with standard deviation were computed using difference of 95% confidence interval. Chi square test was applied for correlation of different variables. P-value of less than 0.05 was considered statistically significant. RESULTS Out of 79 patients who underwent passive ROSO, 38 (48.1%) were males. Mean age of patients was 47.5±7.1 (sd) years. Mean time taken for passive ROSO was 7.31±2.41 (sd) minutes. Pre and post operative intra ocular pressure shows statistically significant (p=0.000) decrease in IOP. Retinal redetachment found in 13 (16.5%) cases during follow up period. CONCLUSION Passive removal of silicone oil with 23 G suture less vitrectomy system is safe and effective in terms of less per operative and post operative complications. In this simple technique, there is less tissue trauma and little time consumed so it provides more comfort to patients and surgeons as well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula...

متن کامل

Active Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?

OBJECTIVES To evaluate the safety and efficacy of active silicone oil removal with a 23-gauge (G) transconjunctival sutureless system. MATERIALS AND METHODS One hundred sixteen eyes of 113 patients who had previous retinal detachment surgery with pars plana vitrectomy and silicone oil injection surgery, and underwent silicone oil removal surgery with 23-G transconjonctival sutureless techniqu...

متن کامل

Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

BACKGROUND The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM g...

متن کامل

Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study

BACKGROUND Characteristic complications have been reported for transconjunctival sutureless vitrectomy, such as postoperative sclerotomy leakage and postoperative hypotony. Particular attention to sclerotomy closure is required in cases of silicone oil tamponade, because postoperative supplementation of silicone oil implies reoperation, whereas postoperative supplement of gas is comparatively e...

متن کامل

A Case of Sympathetic Ophthalmia after 23-Gauge Transconjunctival Sutureless Vitrectomy

PURPOSE We report a case of a sympathetic ophthalmia that occurred after 23-gauge transconjunctival sutureless vitrectomy for a retinal detachment. CASE REPORT A 41-year-old Japanese woman underwent combined phacoemulsification with intraocular lens implantation and 23-gauge transconjunctival sutureless vitrectomy for a rhegmatogenous retinal detachment in the right eye. Endolaser photocoagul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016