چکیده

Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed based on detailed planar analysis of measured three-directional velocity fields [2]. State of the art interpolation and numerical methods were employed to provide optimal quantitative assessment of flow and derived vessel wall parameters such as wall shear stress (WSS). The aim of this study was to evaluate the accuracy of in vivo blood flow and vessel wall parameters determined from transversal planes retrospectively defined on 3D CINE PC data with 3-directional velocity encoding (3D-CINE-3dir.PC) by comparison after registration to conventional 2D CINE PC data with 3-directional velocity encoding (2D-CINE-3dir.PC). Specifically, the influence of spatial and temporal resolution, in several planes along the thoracic aorta was investigated in a volunteer study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methodology for Optimal Quantitative Flow Analysis by planar analysis of CINE Phase Contrast 2D or 3D MR data

Introduction: Time-resolved (CINE) phase contrast (PC) MRI allows measurement of time resolved threedirectional velocities within entire 3D vascular structures [1, 2]. The information contained in the PC data is not limited to volumetric flow, but also includes derived quantities such as wall shear stress (WSS), the viscous drag of blood on the arterial wall, which is believed to play a key rol...

متن کامل

Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation

Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-establish...

متن کامل

Hadamard-Transform k-t PCA for Cine 3D Velocity Vector Field Mapping of Carotid Flow

Introduction Secondary flow patterns in the carotid bifurcation have been found to promote distinct wall shear stress configurations [1]. To study these effects, Computational Fluid Dynamics (CFD) has been utilized with vessel geometries derived from anatomical MR data [2]. Despite the success of CFD methods providing results at very high resolutions, there is a desire to derive flow patterns d...

متن کامل

3D quantification of wall shear stress using finite-element interpolations from 4D flow MR data in the Thoracic Aorta

Background Actual methods to quantify wall shear stress (WSS) are performed on reformatted 2D planes from 4D flow data sets. This approach has the inherit limitation that only a few planes are analyzed on specific locations of the aorta, even though the full 3D velocity field is usually available. Another problem with this approach is that the process of locating 2D planes manually is dependent...

متن کامل

Hemodynamic assessment of the splanchnic arteries with aneurismal dilations using time-resolved three dimensional phase contrast MRA (4Dflow)

Background: Hemodynamic analysis of the splanchnic arteries prior to surgical or catheter interventions for the corresponding arteries is important in order to determine catheter approaches and surgical plannings with considerations of estimated risk of rupture. Purpose: The purpose of the study is two folds; 1) to test the usefulness of time-resolved three dimensional phase contrast MRA (4Dflo...