Load distribution between cephalic screws in a dual lag screw trochanteric nail

نویسندگان

  • Julia Henschel
  • Sebastian Eberle
  • Peter Augat
چکیده

BACKGROUND It has been observed clinically that the Z-effect is a potential cause of failure of an intramedullary nail with two cephalic screws. It describes the migration behavior of the cephalic screws in the femoral head. The primary objective was to examine different cephalic screw configurations and test the load distribution between them as a function of their relative placement and their relative movement in the nail. It has been hypothesized that different cephalic screw positions may have an influence on the stress in the implant and bone and therefore on implant failures, such as the Z-effect. METHODS To quantify the load distribution of a dual cephalic screw intramedullary femoral nail (Citieffe, Calderara di Reno, BO, Italy), a finite element model of the femur, focusing on the loading of the cephalic screws, was prepared. Four different screw lengths (90-105 mm) were examined. The investigation considered the stresses and strains in the bone and implant as well as the relative movement of the screws. RESULTS If the inferior cephalic screw had a shorter length, then the superior one and the femoral nail had to bear higher loads. In that case, the "equivalent von Mises stress" increased up to 10 % at the superior cephalic screw and up to 5 % at the femoral nail. The analysis of the relative movement showed that sliding of the inferior cephalic screw occurred in the nail. The total movement ranged from 0.47 to 0.73 mm for the different screw configurations. CONCLUSIONS The stresses were distributed more equally between the two cephalic screws in the bone and the implant if a longer inferior screw was used. The stresses in the bone and implant were reduced with a longer inferior cephalic screw. Therefore, a configuration using a longer inferior cephalic screw is preferable for trochanteric fracture fixation with a dual cephalic screw intramedullary device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation.

OBJECTIVES To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING Orthopaedic biomechanics laboratory. DESIGN Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset....

متن کامل

Proximal femoral nail for treatment of trochanteric femoral fractures.

PURPOSE To report outcomes of 87 consecutive patients treated with a proximal femoral nail (PFN) for trochanteric femoral fractures. METHODS 17 men and 70 women aged 58 to 95 (mean, 85) years with trochanteric femoral fractures underwent PFN fixation using an intramedullary nail, a lag screw, and a hip pin. Fractures were classified according to the AO system; the most common fracture type wa...

متن کامل

Z-effect after intramedullary nailing systems for trochanteric femur fractures

PURPOSE The aim of this study was to investigate the incidence of Z-effect after dual lag screw intramedullary nailing systems and risk factors contributing to this effect. We hypothesized that long nails provide more neck strength due to a longer lever than short nails and are therefore less likely to develop a misbalance of a higher head compressive strength than neck compressive strength. ...

متن کامل

Proximal femoral nail for treatment of Unstable Trochanteric fractures, Review of Results in 60 cases

Introduction :To review the outcome of 60 patients treated with a proximal femoral nail (PFN) for Unstable trochanteric fractures from Jan 2010 to Dec 2011. Methods: 27 men and 33 women aged 28 to 90 (mean, 63) years with Unstable trochanteric fractures underwent PFN fixation using an cephallo-medullary nail, a lag screw, and a hip pin & Interlocking Bolts. Fractures were classified according t...

متن کامل

Augmentation of proximal femoral nail in unstable trochanteric fractures

INTRODUCTION Biomechanically proximal femoral nail (PFN) is a better choice of implant, still it is associated with screw breakage, cut out of screw through femoral head, Z effect, reverse Z effect, and lateral migration of screws. The purpose of this study is to evaluate the results of augmented PFN in terms of prevention of postoperative complications and failure rates in unstable trochanteri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016