Accurate Position Detection of Sound Source by LabView
نویسندگان
چکیده
This paper introduces a method to detect an accurate position, which includes its distance and direction, of a sound source based on a new Ttype microphone array having four sound sensors in a LabView development environment. The T-type microphone array consists of three linear microphones in the front side and one in the center of the rear side. Existing linear microphone array types have difficulties in detecting a sound source which exists in the back side of the array. However the type proposed in this paper makes omnidirectional detection possible. The T-type also estimates a source distance by comparing two pressure levels from a front sound sensor and a rear sound sensor respectively. The reduction rate of a sound pressure level is used to calculate the source distance. In general, the direction of a sound source is estimated by calculating the time delay between separate sensors, but the technique proposed in this paper uses both the time delay approach mentioned above and the geometrical method with triangular surveying relations for a higher probability value to obtain the high level accuracy of the direction calculation. Sound-related hardware design requires complex signal processing techniques with a difficulty of desired algorithm verification. In this case, LabView can be used to help intuitive PC-based programming and effective algorithm verification.
منابع مشابه
The Kinematic Analysis Of Four Degrees Of Freedom For A Medical Robot And Control It By Labview And Arduino Mega2560 (Simulation And Implementation)
ABSRACTThis study presents the kinematic analysis of a four-degree freedom medical robotic arm using the Matlab and the robotic-tool, the arm was designed using a solid work program, As well as details of the control of the real design of this arm using Arduino Mega 2560, The specialist enters the position to be reached by the automatic arm (injection position), Or moving the arm to any p...
متن کاملLabVIEW implementation of an enhanced nonlinear PID controller based on harmony search for one-stage servomechanism system
This paper presents a practical implementation for a new formula of nonlinear PID (NPID) control. The purpose of the controller is to accurately trace a preselected position reference of one stage servomechanism system. The possibility of developing a transfer function model for experimental setup is elusive because of the lack of system data. So, the identified model has been developed via gat...
متن کاملLabVIEW Based Biomedical Signal Acquisition and Processing
This paper describes a computer based signal acquisition, processing and analysis system using LabVIEW, a graphical programming language for engineering applications. Biomedical signal acquisition has greatly advanced over the years, using many different technologies. E series multifunction data acquisition cards are used for the acquisition of biomedical signals and the appropriate software NI...
متن کاملReal Time Detection and Classification of Single and Multiple Power Quality Disturbance Based on Embedded S- Transform Algorithm in Labview
This paper present the features extraction of the real time voltage signal performed by S-Transform analysis for the purpose of detection and classification of PQ disturbance, which focus on voltage sag, voltage swell and transient. The extracted features will be used as a parameter in detecting and classifying the single and multiple PQ disturbances. As for validation purpose, the real time S-...
متن کاملLabview Based Brain Tumor Area and Length Detection in Ct and Mri Scan Images
The Magnetic Resonance Imaging (MRI), and Computed Tomography (CT) scan plays an important role in Brain Tumor detection. The tumor means abnormal cells growth in a human body. In this project we are find out exact position of brain tumor by using NI LABVIEW software. Here, we create a script in NI Vision Assistant. First acquire gray scale image from MRI and CT scan images and then applying th...
متن کامل