Amoxicillin administrations and its influence on bone repair around osseointegrated implants.

نویسندگان

  • Gabriela Giro
  • Joon In
  • Lukasz Witek
  • Rodrigo Granato
  • Charles Marin
  • Paulo G Coelho
  • Juliana Cama Ramacciato
  • Rogério Heládio Lopes Motta
چکیده

PURPOSE The objective of this study was to evaluate the influence of 4 different amoxicillin administration protocols on osseointegration of dental implants. MATERIALS AND METHODS Thirty-five Wistar rats received an implant in the right tibia and were divided into 5 groups (n = 7): the control group (G1), a group that received a single dose of amoxicillin suspension (40 mg/kg) hour before surgery (G2), a group that received amoxicillin suspension 1 hour before surgery and a 10-mg/kg dose every 12 hours for 3 days (G3), a group that received amoxicillin suspension 1 hour before surgery and a 10-mg/kg dose every 12 hours for 5 days (G4), and a group that received amoxicillin suspension 1 hour before surgery and a 10-mg/kg dose every 12 hours for 7 days (G5). The animals were sacrificed by anesthesia overdose 28 days after implant placement. The samples were retrieved for bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) analyses. RESULTS BIC analysis indicated 3 different statistical groups: G1 plus G2, G3, and G4 plus G5. There was no statistical difference between G1 and G2 or between G4 and G5. G3 presented lower values, with statistical difference for G1 plus G2 and G4 plus G5. Also, a statistical difference was found between G1 plus G2 and G4 plus G5. For BAFO evaluation, no statistical difference was found for the experimental groups. CONCLUSION The results of this study suggest that prolonged use of amoxicillin might have a negative effect on bone formation around implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Effects of ethanol on the osteogenesis around porous hydroxyapatite implants.

Alcohol consumption compromises bone tissue, and thus may either impair or stop the fixation and maintenance of osseointegrated implants. To evaluate the effects of 5% and 15% ethanol on bone neoformation around porous hydroxiapatite implants. Fifteen rats were separated into 3 groups of 5 animals each: control (CT); 5% alcohol (A); and 15% alcohol (AA). After four weeks of ethanol consumption,...

متن کامل

Prosthodontic closure of palatal fistula with osseointegrated implants and onlay bone grafts--case report.

A case treated with onlay bone grafting and simultaneous osseointegrated implant insertion is reported. The patient had an oronasal fistula in the center of the premaxillary region due to failed repair of a bilateral cleft palate. Four fixtures were inserted with onlay bone grafting of the maxillary alveolar ridge. Twelve months postsurgery, one fixture was lost as a result of severe bone resor...

متن کامل

Comparative Evaluation of Osseointegrated Dental Implants Based on Platform-Switching Concept: Influence of Diameter, Length, Thread Shape, and In-Bone Positioning Depth on Stress-Based Performance

This study aimed to investigate the influence of implant design (in terms of diameter, length, and thread shape), in-bone positioning depth, and bone posthealing crestal morphology on load transfer mechanisms of osseointegrated dental implants based on platform-switching concept. In order to perform an effective multiparametric comparative analysis, 11 implants different in dimensions and in th...

متن کامل

An Unusual Bone Loss Around Implants

Pre-implant disease is an inflammatory process that affects the surrounding tissues of a functional osseointegrated implant. It is usually the result of a disequilibrium between the micro-flora and the defense system. This case reports a 57-year-old man with unusual bone loss around dental implants. This was an unusual case of peri-implantitis that occurred only in the implants on one side of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014