Semiconductor detectors allow low-dose-low-dose 1-day SPECT myocardial perfusion imaging.

نویسندگان

  • Rene Nkoulou
  • Aju P Pazhenkottil
  • Silke M Kuest
  • Jelena R Ghadri
  • Mathias Wolfrum
  • Lars Husmann
  • Michael Fiechter
  • Ronny R Buechel
  • Bernhard A Herzog
  • Pascal Koepfli
  • Cyrill Burger
  • Oliver Gaemperli
  • Philipp A Kaufmann
چکیده

UNLABELLED Cadmium zinc telluride (CZT) detectors with linear counting rate response enable count subtraction in sequential scanning. We evaluated whether count subtraction eliminated the need for higher activity doses in the second part of the 1-d stress-rest myocardial perfusion imaging (MPI) protocol. METHODS For 50 patients (mean age ± SD, 66 ± 12 y) with visually abnormal (n = 42) or equivocal (n = 8) adenosine-stress MPI (320 MBq of (99m)Tc-tetrofosmin) on a CZT camera, rest MPI was performed with a low dose (320 MBq) and repeated after injection of an additional 640 MBq of (99m)Tc-tetrofosmin to achieve a standard 3-fold increased dose at rest (960 MBq), compared with stress (320 MBq). Low-dose rest myocardial perfusion images were reconstructed after subtracting the background activity of the preceding stress scan. Segmental percentage tracer uptake of the 2 rest myocardial perfusion images (320 vs. 960 MBq) was compared using intraclass correlation and Bland-Altman limits of agreement. Patient- and coronary territory-based clinical agreement was assessed. RESULTS The standard protocol revealed ischemia in 34 (68%) and a fixed defect in 8 (16%) patients, of whom 33 (97%) and 8 (100%) were correctly identified by low-dose MPI (clinical agreement, 98%). Segmental uptake correlated well between low- and standard-dose rest scans (r = 0.94, P < 0.001; Bland-Altman limits of agreement, -11 to +11%). Defect extent was 14.4% (low-dose) versus 13.1% (standard-dose) at rest (P = not statistically significant) and 26.6% at stress (P < 0.001 vs. rest scans). CONCLUSION These promising results suggest that accurate assessment of ischemic myocardial disease is feasible with a low-dose-low-dose 1-d SPECT MPI protocol using a CZT device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion SPECT using cadmium-zinc telluride detectors in the rat

BACKGROUND The aims of this study were (1) to evaluate the impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion single-photon emission computed tomography (SPECT) using cadmium-zinc telluride (CZT) detectors and (2) to determine how these factors affect measured infarct size in the in vivo rat. METHODS Twenty-four healthy and ...

متن کامل

Clinical Performance of the Discovery NM530c in Japanese Patients

The Discovery NM530 is a new generation of SPECT cameras equipped with semiconductor cadmium-zinctelluride (CZT) detector technology. It provides a shorter scan time and reduces the patient’s radiation exposure wthout loss of image quality compared with the conventional Anger camera. Combined supine and prone imaging with the Discovery NM530c is useful for reducing the false-positive rate in th...

متن کامل

The Status of Stress Myocardial Perfusion Imaging Using 99mTc Pharmaceuticals in Japan: Results from a Nationwide Survey

Objective(s): To appropriately use one-day myocardial perfusion imaging (MPI) with 99mTc radiopharmaceuticals (i.e. to avoid shine-through artifacts), injection doses need to be optimized and dose ratios between the 1st and 2nd scans should be maintained at ≥ 3. However, the current state of practice in Japan is unclear. Thus, the aim of this study was to clarify the details of MPI protocols us...

متن کامل

High-Sensitivity and High-Resolution SPECT/CT Systems Provide Substantial Dose Reduction Without Compromising Quantitative Precision for Assessment of Myocardial Perfusion and Function.

UNLABELLED There is increasing concern about radiation exposure from myocardial perfusion SPECT (MPS). γ-cameras with solid-state cadmium-zinc-telluride (CZT) detectors have better count sensitivity and spatial resolution than conventional sodium iodine detectors, allowing for significant reductions in radiotracer dose or acquisition time. This study aimed to demonstrate the capability of a hyb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011