Comparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections
ثبت نشده
چکیده
Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at 6% drift at these connections. As a result of the extra loads applied, little damage was observed. In the last phase, the four connections tested in the first phase were repaired using epoxy resin and then retested. The results from the tests on the repaired precast and the undamaged specimens showed that the repaired specimens were sufficiently strong, thus proving that repair to damaged precast beam to column post tensioned connections can be undertaken. Keywords—Precast beam to column connection, momentresisting connection; post-tensioned connections, repair of precast connections.
منابع مشابه
Post-Tensioned Steel Connections Self-Centering Behavior Using the Finite Element Method
Due to lack of the proper and well behavior of steel moment-resisting connections subjected to the great and major earthquakes, excessive researches have been conducted to mitigate the damages on the primary elements and connections. Therefore, elimination of residual drift and increasing the plastic rotation capacity for the connectors in the panel zone are required. The main purpose of this s...
متن کاملInfluential Factor in Improving the Seismic Performance of the Kaiser Bolted Bracket Moment Connection
Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...
متن کاملNumerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames
This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...
متن کاملSeismic Behavior of Prefabricated Column-Footing Connection
Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...
متن کاملNon-Linear Behavior of New (FSFN) Moment Resisting Connections in Comparison to the Existing KBB Connections in Steel Frames
After Northridge (1994) and Kobe (1995) earthquakes, several studies have been conducted to improve the seismic performance of steel structures. In this investigation, new steel moment-resisting connections (FSFN) developed by the authors, were studied by the non-linear numerical analysis. These connections were single-sided beam-to-column assemblies that are representative of exterior beam-to-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015