Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.
نویسندگان
چکیده
BACKGROUND Biodegradable polymer-coated stents may have positive effects on arterial healing, and reduce the need for prolonged antiplatelet therapy. AIM To assess the vascular effects of the biodegradable polymer proposed as a stent coating, as well as to evaluate inhibition of intimal hyperplasia by Biodegradable Polymer-Coated Paclitaxel-Eluting Stents (BP-PES, LUC-Chopin, Balton) in porcine coronary arteries. METHODS A total of 19 stents were implanted into the coronary arteries of 13 pigs: seven bare metal stents (BMS), six biodegradable polymer-coated stents (PCS) and six BP-PES. Animals were followed up for 28 days. Additionally, 11 BP-PES were implanted in four pigs which were followed for 90 days. Twenty eight and 90 days after stent implantation, the control coronary angiography was performed. Subsequently, the animals were sacrificed, their hearts were extracted and the coronary arteries were isolated for further histopathological analysis. RESULTS After 28 days, BP-PES stents effectively limited neointimal hyperplasia in comparison to the control group (LL = 0.48 +/- 0.06 for BMS vs 0.87 +/- 0.16 for PCS vs 0.15 +/- 0.05 mm for BP-PES; p < 0.05). However, at three months, a 'catch-up' effect in neointimal formation was observed. Histopathology demonstrated favourable safety, with complete endothelialisation and inflammation significantly decreased between one and three months. CONCLUSIONS It seems that the biodegradable polymer-coated, paclitaxel-eluting stent examined in the present study is both safe and feasible. This supports the first such study in humans being conducted.
منابع مشابه
New frontiers in cardiology: drug-eluting stents: Part II.
Preclinical Data Unlike other antimitotic agents, paclitaxel shifts the cytoskeleton equilibrium toward assembly, leading to reduced vascular cell proliferation, migration, and signal transduction.2 Paclitaxel is highly lipophilic, resulting in a rapid cellular uptake and a long-lasting effect in the cell.3 NIR stents (Boston Scientific Corp) coated with poly(lactide-co-caprolactone) copolymer ...
متن کاملPaclitaxel balloon coating, a novel method for prevention and therapy of restenosis.
BACKGROUND Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non-stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. METHODS AND RESULTS Stainless ...
متن کاملEvaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.
OBJECTIVES We sought to evaluate a new second-generation drug-eluting stent (DES), comprising a slow-release biodegradable polylactide coglycolide (PLGA) polymer and low-dose paclitaxel on a thin-strut cobalt chromium stent platform, in a clinically relevant animal model. BACKGROUND Our previous work demonstrated subacute vascular toxicity and necrosis triggering late excess neointima in pig ...
متن کاملVascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries.
BACKGROUND Although durable polymer coated drug-eluting stents (DES) are standard care in percutaneous coronary interventions, new stent platforms employing biodegradable polymer based drug delivery are increasingly being used in clinical practice. AIM To evaluate the short- (28 days) and medium-term (90 days) vascular effects of the new biodegradable polymer coated sirolimus-eluting stent - ...
متن کاملAnti-inflammatory Effect of Abciximab-Coated Stent in a Porcine Coronary Restenosis Model
The aim of this study was to examine the anti-inflammatory effect of abciximab-coated stent in a porcine coronary overstretch restenosis model. Ten abciximab-coated stents, ten sirolimus-eluting stents (SES), and ten paclitaxel-eluting stents (PES) were deployed with oversizing (stent/artery ratio 1.3:1) in porcine coronary arteries, and histopathologic analysis was done at 28 days after stenti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kardiologia polska
دوره 68 5 شماره
صفحات -
تاریخ انتشار 2010