Saline contrast hysterosonography in abnormal uterine bleeding: a systematic review and meta-analysis.
نویسندگان
چکیده
OBJECTIVE To assess the diagnostic accuracy of saline contrast hysterosonography in the evaluation of the uterine cavity in women complaining of abnormal uterine bleeding. DESIGN A systematic review and meta-analysis of diagnostic studies that compared saline contrast hysterosonography to a gold standard diagnosis based on either hysteroscopy with or without histological sampling or to hysterectomy. SETTING University Hospital. SAMPLE Twenty-four studies (including 2278 procedures). METHODS Electronic databases were searched for relevant studies and references were cross checked. Validity was assessed and data were extracted independently by two authors. Heterogeneity was calculated, studies were plotted in an ROC area and data were pooled. Subgroup analysis was performed according to the validity area. MAIN OUTCOME MEASURES The success rate of saline contrast hysterosonography. The pooled sensitivity, specificity, likelihood ratio's and post-test probabilities of saline contrast hysterosonography on the prediction of uterine cavity abnormality. RESULTS The largest population of homogeneous data were the studies with complete verification. In these studies, the pooled sensitivity and pooled specificity of saline contrast hysterosonography in uterine cavity evaluation were respectively 0.95 (95% CI 0.93 to 0.97) and 0.88 (95% CI 0.85 to 0.92), the likelihood ratios were respectively 8.23 (95% CI 6.2 to 11) and 0.06 (95% CI 0.04 to 0.09) and the post-test probabilities were respectively 0.91 (95% CI 0.89 to 0.94) and 0.07 (95% CI 0.04 to 0.10). The overall success rate of saline contrast hysterosonography was 93% (95% CI 92% to 94%). The feasibility of saline contrast hysterosonography in postmenopausal women (success rate 86.5%, 95% CI 83.2 to 89.8) is significantly lower (P < 0.01) compared with premenopausal women (success rate 95%, 95% CI 94% to 96%). CONCLUSION Saline contrast hysterosonography is accurate in the evaluation of the uterine cavity in pre- and postmenopausal women suffering from abnormal uterine bleeding. The feasibility of saline contrast hysterosonography is high, although significantly better in premenopausal women compared with postmenopausal women. We conclude that saline contrast hysterosonography, in combination with an endometrium aspiration if necessary, can become the standard diagnostic procedure in women with abnormal uterine bleeding.
منابع مشابه
Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities
Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...
متن کاملDiagnostic value of saline contrast sonohysterography comparing with hysteroscopy for detecting endometrial abnormalities in women with abnormal uterine bleeding
BACKGROUND Abnormal uterine bleeding is a common presentation of uterine abnormalities among premenopausal and postmenopausal women. OBJECTIVE To evaluate and compare the diagnostic accuracy of saline contrast sonohysterography and hysteroscopy for detecting the cause of abnormal uterine bleeding. MATERIALS AND METHODS A total of 65 women with abnormal uterine bleeding were enrolled in this...
متن کاملOnm-1: Imaging in Abnormal Uterine Bleeding
Abnormal uterine bleeding is any bleeding from the uterus other than normal monthly period. Having extremely heavy bleeding during period can also be considered abnormal uterine bleeding. Dysfunctional uterine bleeding (DUB) is heavy or irregular menstrual bleeding that is not caused by an underlying anatomical abnormality, such as a fibroid, lesion, or tumor. DUB is the most common type of abn...
متن کاملComparison of transvaginal sonography and saline contrast sonohysterography in women with abnormal uterine bleeding: correlation with hysteroscopy and histopathology.
BACKGROUND Transvaginal ultrasound is used conventionally as initial investigation of patients with abnormal uterine bleeding but saline contrast sonohysterography is a better technique to reliably distinguish focal from diffuse endometrial lesions. This study was performed to compare the ability of transvaginal ultrasonography and saline infusion sonohysterography as initial modality for the d...
متن کاملEP29.04: Hysterosonography performed in bleeding time in the exploration of abnormal uterine bleeding: diagnostic value.
Methods In this prospective study, we included 216 patients visiting our department for abnormal uterine bleeding. All patients had a transvaginal ultrasound with doppler study and an hysterosonography. Secondly, the patients in whom we diagnosed a suspected organic lesion were addressed to an endoscopic or surgical procedure with pathological examination. Initially we evaluated the feasibility...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BJOG : an international journal of obstetrics and gynaecology
دوره 110 10 شماره
صفحات -
تاریخ انتشار 2003