Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system.

نویسندگان

  • Carine Choleau
  • Petr Dokladal
  • Jean-Claude Klein
  • W Kenneth Ward
  • George S Wilson
  • Gérard Reach
چکیده

Due to the lag between sugar intake and the beginning of recovery from hypoglycemia, it is necessary to intervene in an anticipatory way if one wants to prevent, not only detect, hypoglycemia. This article presents the principle of a hypoglycemia prevention system based on risk assessment. The risk situation can be defined as the moment when the system estimates that the glucose concentration is expected to reach a hypoglycemia threshold in less than a given time (e.g., 20 min). Since there are well-known discrepancies between blood and interstitial glucose concentrations, the aim of this experimental study performed in nondiabetic rats was first to validate this strategy, and second to determine whether it can work when the glucose concentration is estimated by a glucose sensor in subcutaneous tissue rather than in blood. We used a model of controlled decrease in blood glucose concentration. A glucose infusion, the profile of which mimicked the appearance of glucose from an intragastric load, was administered either when hypoglycemia was detected or on the basis of risk recognition. Despite the lag between the beginning of the load and that of the increase in blood glucose concentration, which was in all experiments 15-20 min, hypoglycemia was fully prevented without overshoot hyperglycemia in the groups of rats in which the glucose load was started when the hypoglycemia risk was detected, on the basis of either blood or interstitial glucose concentration. This was, of course, not the case when the same glucose load was infused at the detection of the hypoglycemia threshold.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Use of continuous glucose monitoring in the detection and prevention of hypoglycemia.

Intensive diabetes therapy is complicated by an increased rate of hypoglycemia and the development of hypoglycemia unawareness. This presentation focuses on the potential role of real-time continuous glucose monitoring (CGM) in preventing hypoglycemia, and in overcoming this barrier to the implementation of intensive therapy. Issues to be discussed include the differences between capillary bloo...

متن کامل

Continuous glucose monitoring reveals hypoglycemia risk in elderly patients with type 2 diabetes mellitus

AIMS/INTRODUCTION The incidence of type 2 diabetes is higher in elderly patients, in whom this disease is associated with dementia, falling, stroke and death. We utilized a continuous glucose monitoring device to analyze the relationship between hypoglycemia and diabetes treatments to identify risk factors for hypoglycemia (defined as a blood glucose level <70 mg/dL). MATERIALS AND METHODS We...

متن کامل

Characteristics of glucose metabolism indexes and continuous glucose monitoring system (CGMS) in patients with insulinoma

AIMS Analyze the clinical applicability of glucose metabolism indexes and continuous glucose monitoring data on the qualitative diagnosis of insulinoma. METHODS Involve 22 patients with insulinoma (insulinoma group), 11 patients with hypoglycemia (hypoglycemia group) and 31 people with normal glucose tolerance (control group). HbA1c, fasting blood glucose (FBG), insulin (FINS) and C-peptide (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes

دوره 51 11  شماره 

صفحات  -

تاریخ انتشار 2002