A new phantom using polyethylene glycol as an apparent diffusion coefficient standard for MR imaging.

نویسندگان

  • Ryohei Matsuya
  • Masahiro Kuroda
  • Yoshitsugu Matsumoto
  • Hirokazu Kato
  • Hidenobu Matsuzaki
  • Junichi Asaumi
  • Jun Murakami
  • Kazunori Katashima
  • Masakazu Ashida
  • Takanori Sasaki
  • Tetsuro Sei
  • Kengo Himei
  • Kuniaki Katsui
  • Norihisa Katayama
  • Mitsuhiro Takemoto
  • Susumu Kanazawa
  • Seiichi Mimura
  • Seiichiro Oono
  • Takuichi Kitayama
  • Seiji Tahara
  • Keiji Inamura
چکیده

In recent years, magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) has seen wide clinical use, such as for early detection of cerebrovascular diseases and whole body screening for tumors. The apparent diffusion coefficient (ADC) standard phantom, which mimics the ADC values of several lesions in the body, is indispensable for the development of new pulse sequences for DWI, such as diffusion-weighted whole-body imaging with background body-signal suppression (DWIBS). However, information on the ADC values of the previously reported ADC standard phantoms is limited, because these phantoms were made using only a few different materials at a limited range of concentrations, and the ADC values were measured only at certain temperatures. It has been considered difficult, if not impossible, to create a phantom that provides arbitrary ADC values, because it is difficult to calculate the concentrations of the materials and the temperature at ADC measurement. In this study, we used polyethylene glycol (PEG) as a phantom material, and developed an empirical formula to calculate the PEG concentration at any measurement temperature to obtain arbitrary ADC values of the phantom. DWI images of phantoms made using seven different PEG concentrations were taken under heating from 17 to 46 degrees C at 1 degrees C intervals. Using ADC values calculated from these DWI images, we developed two empirical formulas: i) an empirical formula to calculate the ADC values of phantoms made using any PEG concentration at any measurement temperature; and ii) an empirical formula to calculate PEG concentrations to obtain arbitrary ADC values at any measurement temperature. We inspected the accuracy of these empirical formulas by newly made PEG phantoms. A comparison between the ADC values calculated with the empirical formulas and the measured ADC values confirmed the high accuracy of these formulas. PEG phantoms are safe, inexpensive and easy to make, compared with the previously reported ADC standard phantoms. Our empirical formulas enable us to calculate PEG concentrations that provide arbitrary ADC values at any measurement temperature. The empirical formulas could be used within a range of ADC values from 0.37x10(-3) to 3.67x10(-3) mm(2)/s, PEG concentrations from 0 to 120 mM, and measurement temperatures from 18 to 45 degrees C. Using these formulas, it would be possible to make standard phantoms that mimic the ADC values of any clinical lesions. The PEG phantom might thus be an excellent new ADC standard phantom for MRI with DWI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom

OBJECTIVE To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. MATERIALS AND METHODS Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, ...

متن کامل

A new phantom and empirical formula for apparent diffusion coefficient measurement by a 3 Tesla magnetic resonance imaging scanner

The aim of this study was to create a new phantom for a 3 Tesla (3T) magnetic resonance imaging (MRI) device for the calculation of the apparent diffusion coefficient (ADC) using diffusion-weighted imaging (DWI), and to mimic the ADC values of normal and tumor tissues at various temperatures, including the physiological body temperature of 37°C. The phantom was produced using several concentrat...

متن کامل

In vitro experimental study of the relationship between the apparent diffusion coefficient and changes in cellularity and cell morphology.

Diffusion-weighted magnetic resonance imaging (MRI) is frequently used clinically, and is available for the whole-body screening for tumors. The exact mechanism by which the apparent diffusion coefficient (ADC) value decreases in tumorous tissue remains unclear, although various theories have been proposed, including intracellular and extracellular factor theories. It is impossible to distingui...

متن کامل

Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging.

UNLABELLED With the recent advent of integrated PET/MR hybrid systems, the need for simultaneous PET and MR phantom measurements arises. Phantom fluids that are used in stand-alone MR systems, especially in larger phantoms and at a high magnetic field strength, are not necessarily applicable in PET imaging and vice versa. In this study, different approaches to fluid selection were considered an...

متن کامل

Diffusion imaging of the human brain: a new pulse sequence application for a 1.5-T standard MR system.

We developed a new pulse sequence and investigated whether the anisotropic diffusion in the human brain can be detailed with a standard whole-body MR imager. Apparent diffusion coefficient maps were produced by the proposed sequence using a 1.5-T MR unit. The sequence employed simultaneous application of three orthogonal gradients to achieve an optimal signal attenuation for imaging the brain w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of oncology

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2009