Quantitation of hemoglobin A1a+b and hemoglobin A1c by automated "high-performance" liquid chromatography.

نویسندگان

  • C A Gruber
  • M D Koets
چکیده

The glycosylated hemoglobins A1a+b and A1c have been rapidly and precisely quantitated in 5-micro L samples of human blood hemolysate (approximately 240 micrograms of hemoglobin) by cation-exchange column chromatography. Total chromatographic is 22.0 min. Proportions of Hb A1c range from 3.85 to 6.71% in normal individuals and from 4.23 to 19.90% in diabetic subjects. Within-day variation was 1.58 and 1.10% for mean Hb A1c proportions of 4.92 and 10.32%, respectively. Hb A1c and Hb A1 are stable in hemolysates stored at 4 degrees C for as long as seven days, and indefinitely under liquid nitrogen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid quantitation of hemoglobin S in sickle cell patients using the Variant II Turbo analyzer.

A rapid ( approximately 90 sec), fully automated method is described for quantifying hemoglobin S (HbS) by high performance liquid chromatography (HPLC) using the Bio-Rad Variant II Turbo analyzer. Although this instrument is designed to quantify only blood hemoglobin A1c (HbA1c), we show that it can also quantify accurately, without modification, HbS levels in sickle cell patients, provided th...

متن کامل

Separation of hemoglobin types by cation-exchange high-performance liquid chromatography.

The use of a recently developed cation-exchange HPLC packing material for the separation of hemoglobin types in human blood has been investigated. Adult and newborn hemolysates from normal individuals and from subjects with hemoglobin disorders were analyzed using a weak cation carboxymethyl-bonded phase on 5-micron-particle-size silica. Elution was accomplished using a Bistris (2-[bis(2-hydrox...

متن کامل

Evaluation of a nucleic acid-based cross-linking assay to screen for hereditary hemochromatosis in healthy blood donors.

14. 13. Chung BH, Segrest JP, Ray MJ, Brunzell JD, Hokanson JE, Krauss RM, et al. Single vertical spin density gradient ultracentrifugation. Methods Enzymol 1986;128:181–209. 14. Khuu HM, Robinson CA, Goolsby K, Hardy RW, Konrad RJ. Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c. Arch Pathol Lab Med 1999;123:763–7. 15. Khuu HM, Robinson CA, Briss...

متن کامل

A Rare Hemoglobin Variant Which Interfered Hemoglobin A1C Result: Hemoglobin South Florida [β1(NA1)Val>Met, GTG>ATG; HBB: c.4G>A] [Hemoglobin A1c Sonucunu Etkileyen Nadir Hemoglobin Varyantı: Hemoglobin South Florida (β1(NA1)Val>Met, GTG>ATG; HBB: c.4G>A)]

Hb South Florida is a rare hemoglobin beta chain variant that is not associated with any clinical disorder. We report a heterozygous Hb South Florida [β1(NA1)Val>Met, GTG>ATG; HBB:c.4G>A] case determined during a premarital screening program. This hemoglobin variant can be identified with high performance liquid chromatography analysis confirmed with DNA sequencing. We emphasize in our study th...

متن کامل

Title : Changes in hemoglobin F levels in pregnant women unaffected by clinical

Complete automation of high-performance liquid chromatography (HPLC) for determination of hemoglobin F (%Hb F) and hemoglobin A1c (%Hb A1c) levels has made this procedure available in many clinical laboratories. However, the physiological changes in %Hb F during pregnancy and the effects of physiological and supraphysiological levels of %Hb A1c on measurement of %Hb F have not been studied exte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 11  شماره 

صفحات  -

تاریخ انتشار 1979