Clinical testing of implanted pacemakers.
نویسندگان
چکیده
The function of implanted pacemakers was assessed at a special pacemaker clinic at intervals of three to six months. Measurements of the basic discharge rate of the pacemaker were made and the waveform was recovered from skin electrodes and displayed on an oscilloscope screen. The impulse was photographed from the screen and subsequent waveform analysis was carried out. Reproducible results were obtained for measurements of peak amplitude and impulse duration provided unipolar electrodes were in use and the patients were studied in the same position. The range of variation of the measurements during the lifetime of different models of normally functioning pacemakers is given. Test measurements taken before failing pacemakers were removed have been correlated with the subsequently established cause of failure and the waveform analysis test has been shown to be clinically reliable. The value of the test depended largely upon the type of pacemaker but it correlated well with rate changes in pacemakers designed to slow as battery exhaustion developed. The clinical value of waveform analysis tests is in the diagnosis of exit block, electrode failure, and premature battery exhaustion and in determining the optimum time for pacemaker replacements. The indications for replacement of pacemakers at the National Heart Hospital are given. Initial experience with an automatic analyser with three types of pacemaker shows that rapid measurements of the waveform parameters can be achieved with accuracy.
منابع مشابه
Temporary inhibition of permanently implanted demand pacemakers.
Temporary inhibition of permanently implanted demand pacemakers has been previously described. Demand pacemakers may be inhibited by waving a magnet over the region of the pacemaker generator or by chest wall stimulation. The former may not inhibit most of the bipolar pacemakers, whereas the latter may be time consuming and may casue patient discomfort. Another method is described which utilize...
متن کاملAnalysis of charges and complications of permanent pacemaker implantation in the cardiac catheterization laboratory versus the operating room.
During the last two decades, an increasing number of permanent pacemakers have been implanted outside of the operating room (OR) by nonsurgeons. Previous investigators have demonstrated that pacemakers can be safely implanted in the cardiac catheterization laboratory with no increase in complications or infections. This is the first study of its kind to simultaneously evaluate cost, length of h...
متن کاملCompatibility of automatic threshold tracking pacemakers with previously implanted pacing leads in children.
The Autocapture function controls and optimizes the amplitude of the pacing pulse and saves energy. The manufacturer recommends using a special low polarization, low threshold bipolar Pacesetter lead for the Autocapture function. The purpose of this study was to evaluate the compatibility of Autocapture with previously implanted pacing leads. The study included 15 patients (mean age 13.6 +/- 3....
متن کاملAnesthetic implications of implanted pacemakers: a case study.
Pacemakers and the underlying pathophysiologies leading to their implantation present challenges to the anesthetist. This case report discusses the anesthetic management of a patient with an implanted pacemaker. A case is presented of an 80-year-old female who was found unresponsive in a parking lot. She was diagnosed with a right parietal subdural hematoma. She underwent an emergency craniotom...
متن کاملExperience with Implanted Pacemakers: Technical Considerations.
Between April 1960 and September 1964, 79 patients were treated with implanted pacemakers. We record here the technical difficulties encountered and the steps taken to overcome them. In all cases the indication for artificial pacing was failure of medical treatment to prevent Stokes-Adams attacks or to relieve cardiac failure due to a slow pulse. Most, but not all, patients were in complete hea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 26 2 شماره
صفحات -
تاریخ انتشار 1971