In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients

نویسندگان

  • Ji-Hoon Bae
  • Ali Hosseini
  • Kyung-Wook Nha
  • Sang-Eun Park
  • Tsung Yuan Tsai
  • Young-Min Kwon
  • Guoan Li
چکیده

PURPOSE This study compared in vivo kinematic differences between Caucasian and South Korean patients after a posterior-substituting total knee arthroplasty (PS-TKA). MATERIALS AND METHODS In vivo motions of 9 Caucasian and 13 South Korean knees with a PS-TKA during weight bearing single leg lunge were determined using a dual fluoroscopic imaging technique. Normalized tibiofemoral condylar motions and articular contact locations were analyzed. RESULTS Femoral condylar motions of the two groups showed a similar trend in anteroposterior translation, but the South Korean patients were more anteriorly positioned than the Caucasian patients at low flexion and maximal flexion angles in both medial and lateral compartments (p<0.05). Mediolateral femoral condyle translations were similar between the two groups. For tibiofemoral articular contact kinematics, the South Korean patients had significantly more anterior contact locations at the medial compartment at low flexion angles, and more lateral contact locations at the lateral compartment at 0° and 90° flexion compared to the Caucasian patients (p<0.05). The South Korean patients had significantly larger distances between the medial and lateral contact locations at 60° and 90° flexion compared to the Caucasian patients (p<0.05). CONCLUSIONS The study revealed that while the Caucasian and South Korean knees had similar femoral condylar motions, after PS-TKA the South Korean patients showed different articular contact point kinematics compared to the Caucasian patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematic gait parameters changes in patients after total knee arthroplasty. Comparison between cruciate-retaining and posterior-substituting design.

PURPOSE The patients expect optimal knee function after Total Knee Arthroplasty. It is necessary to apply appropriate surgical technique and supervised physical therapy. The optimal management of posterior cruciate ligament remains controversial. Both implant designs, i.e., cruciate retaining and posterior substituting, allow the orthopedic surgeon to achieve excellent clinical outcomes, as mea...

متن کامل

Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study.

We performed a prospective, randomised trial of 44 patients to compare the functional outcomes of a posterior-cruciate-ligament-retaining and posterior-cruciate-ligament-substituting total knee arthroplasty, and to gain a better understanding of the in vivo kinematic behaviour of both devices. At follow-up at five years, no statistically significant differences were found in the clinical outcom...

متن کامل

Relationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery

Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...

متن کامل

Similar outcome after retention or sacrifice of the posterior cruciate ligament in total knee arthroplasty

The purpose of this study was to answer 2 questions: Does the posterior cruciate ligament (PCL) produce femoral rollback in a single-design, cruciate-sparing total knee arthroplasty (TKA)? Does the PCL prevent posterior tibial displacement when it is retained after a single-design, cruciate-sparing TKA? Knee kinematics and limits of motion were measured with the knees in the following states: (...

متن کامل

In vitro investigation of knee joint kinematics following cruciate retaining versus cruciate sacrificing total knee arthroplasty.

The aim of this biomechanical study was to investigate knee joint kinematics following total knee arthroplasty. We compared eight congruent posterior cruciate ligament retaining and four ultracongruent cruciate sacrificing Natural Knee prostheses to the untreated human cadaveric knee joint. A six-degree-of-freedom testing device was used to evaluate knee joint kinematics with a load of 300 Newt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016