ARX-derived auditory evoked potential index and bispectral index during the induction of anesthesia with propofol and remifentanil.

نویسندگان

  • Gunter N Schmidt
  • Petra Bischoff
  • Thomas Standl
  • Malte Issleib
  • Moritz Voigt
  • Jochen Schulte Am Esch
چکیده

UNLABELLED A new commercial auditory evoked potential (AEP) monitor (A-line AEP monitor) was developed to calculate an index (ARX AEP index; AAI) by automatically using the amplitudes and latencies of the AEP. We investigated 30 patients before spine surgery. AAI; bispectral index (BIS); relative (%) delta, theta, alpha, and beta; spectral edge frequency; median frequency; mean arterial blood pressure; heart rate; and oxygen saturation were obtained simultaneously during stepwise (1.0 micro g/mL) induction of target-controlled propofol concentration until 5.0 micro g/mL, followed by an infusion of 0.3 micro g. kg(-1). min(-1) of remifentanil. Every minute, the patients were asked to squeeze the observer's hand. Prediction probability (Pk), receiver operating characteristic, and logistic regression were used to calculate the probability to predict the conditions AWAKE, UNCONSCIOUSNESS (first loss of hand squeeze), and steady-state ANESTHESIA (5.0 micro g/mL of propofol and 0.3 micro g. kg(-1). min(-1) of remifentanil). Although a statistically significant difference among the conditions was observed for AAI, BIS, mean arterial blood pressure, median frequency, and %alpha, only AAI and BIS were able to distinguish UNCONSCIOUSNESS versus AWAKE and ANESTHESIA versus AWAKE with better than Pk = 0.90. The modern electroencephalographic variables AAI and BIS were superior to the classic electroencephalographic and hemodynamic variables to distinguish the observed anesthetic conditions. IMPLICATIONS The modern electroencephalographic ARX-derived auditory evoked potential index and the bispectral index were superior to the classic electroencephalographic and hemodynamic variables for predicting anesthetic conditions. Variables derived from the auditory evoked potential did not provide an advantage over variables derived from spontaneous electroencephalogram.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه‌ای انفوزیون مداوم رمی‌فنتانیل و پاراستامول بر میزان عمق بیهوشی با مونیتورینگ BIS در اعمال جراحی اندوسکوپی سینوس

    Background & Aim: Paracetamol is a non-opioid and non-NSAID(non non-steroidal anti-inflammatory drug) analgesic with central function. Analgesic effect of paracetamol is similar to opioids and NSAIDs but different from them in terms of side effects. Remifentanil is a short-acting opioid. In our study, we assess the effect of these two drugs on the depth of anesthesia using BIS monitoring. B...

متن کامل

Comparative Evaluation of the Cerebral State Index Tm and Bispectral Index Tm Monitoring during Propofol -remifentanil Anesthesia for Open Heart Surgery

Objective: The Cerebral State index (CSI) is a new index based on electroencephalogram to monitor depth of anesthesia. Transferring guidelines for titration of the Bispectral index (BIS) to the CSI depends on their compatibility. We compared the relationship between BIS and CSI values during propofol-remifentanil anesthesia. Methods: Forty one adult patients about to have open heart surgeries w...

متن کامل

Somatosensory Evoked Potentials suppression due to remifentanil during spinal operations; a prospective clinical study

BACKGROUND Somatosensory evoked potentials (SSEP) are being used for the investigation and monitoring of the integrity of neural pathways during surgical procedures. Intraoperative neurophysiologic monitoring is affected by the type of anesthetic agents. Remifentanil is supposed to produce minimal or no changes in SSEP amplitude and latency. This study aims to investigate whether high doses of ...

متن کامل

Total Intravenous Anesthesia for Neurosurgical Procedures in Narcoleptic Patients: Two Case Reports

INTRODUCTION Narcoleptic patients may be at increased risk of prolonged emergence, postoperative hypersomnia, apneic episodes, and sleep paralysis after general anesthesia. Modafinil is the first-line treatment, however, the implication it has on general anesthesia is not clear. This report present 2 cases of narcoleptic patients medicated with modafinil that were submitted to total intravenous...

متن کامل

Do we need bispectral index monitoring during total intravenous anesthesia for lumbar discectomies?

The aim of this study was to investigate the effect of bispectral index (BIS) monitoring on hemodynamic parameters, drug consumption and awareness during total intravenous anesthesia (TIVA) with remifentanil and propofol in lumbar discectomies. After institutional ethical committee approval, ASAI-II 56 patients were divided as control and BIS groups. Anesthesia was induced by bolus remifentanil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 97 1  شماره 

صفحات  -

تاریخ انتشار 2003