Corneal thickness measurements with Scheimpflug and slit scanning imaging techniques in keratoconus
نویسندگان
چکیده
PURPOSE To determine the repeatability of corneal thickness measurements with Scheimpflug (Pentacam) and slit scanning (Orbscan) imaging techniques in different grades of keratoconus. METHODS This study was conducted as a cross-sectional research. Imaging with Orbscan and Pentacam was performed on patients with different grades of keratoconus. With each device, 3 measurements were taken at 10 min intervals. Repeatability indices in different grades of keratoconus were calculated for each device. RESULTS Seventy-four eyes of 42 keratoconus patients were enrolled. Repeatability index (RI) of central corneal thickness (CCT) measurements in keratoconus grade 1, 2, and 3, were 12.8, 9.9, and 24.2 with Pentacam, and 23.6, 26.3, and 59.3 with Orbscan, respectively. For the thinnest point, these figures were 9.6, 8.0, and 35.7 with Pentacam and 19.5, 16.6, and 26.8 with Orbscan, respectively. The 95% limit of agreement (LOA) between Pentacam and Orbscan in measuring CCT and thinnest point in grade 1 were -25.5-47.7 mic and -33.3-32.8 mic, respectively. These results for grade 2 were -9.8-50.6 mic and -26.2-43.7 mic, respectively. In grade 3, 95% LoA were -20-64.6 mic and -31.4-60.5 mic, respectively. CONCLUSIONS The results of this study showed that although repeated measurements of the CCT with Orbscan and Pentacam are strongly correlated, repeatability values of CCT measurements significantly decrease at more advanced grades of keratoconus. In all keratoconus grades, repeatability of CCT measurements was better with Pentacam than Orbscan. These findings indicate that corneal thickness readings have less validity in patients with advanced keratoconus.
منابع مشابه
Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography.
AIM To compare the anterior segment measurements obtained by rotating Scheimpflug camera (Pentacam) and Scanning-slit topography (Orbscan IIz) in keratoconic eyes. METHODS A total of 121 patients, 71 males (58.7%) and 50 females (41.3%) (214 eyes) with the diagnosis of keratoconus (KC) were enrolled in this study. Following diagnosis of KC by slit-lamp biomicroscopic examination, central corn...
متن کاملComparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.
PURPOSE To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. DESIGN Experimental study. PARTICIPANTS Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. METHODS Corneal thickness measurements were compared among the 3 me...
متن کاملCorneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system.
PURPOSE To evaluate agreement in central corneal thickness (CCT), keratometry, and anterior and posterior elevation map measurements in normal corneas between a combined Placido-Scheimpflug system and a combined Placido-scanning-slit elevation topography system. SETTING Department of Cataract & Refractive Surgery, Rothschild Foundation, Paris, France. DESIGN Evaluation of diagnostic test or...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملCentral Corneal Thickness Measurement Using Ultrasonic Pachymetry, Rotating Scheimpflug Camera, and Scanning-slit Topography Exclusively in Thin Non-keratoconic Corneas
PURPOSE To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. METHODS We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best ...
متن کامل