New Three-Dimensional Echocardiographic System Using Digital Radiofrequency Data—Visualization and Quantitative Analysis of Aortic Valve Dynamics With High Resolution

نویسنده

  • Michael Handke
چکیده

Background—Common 3D systems have only limited spatial and temporal resolution (frame rate of 25 Hz). Thin structures such as cardiac valves are not imaged exactly; rapid movement patterns cannot be precisely recorded. The objective of the present project was to achieve radiofrequency (RF) data transmission to the 3D workstation to improve image resolution. Methods and Results—A commercially available echocardiographic system (5-MHz transesophageal echocardiography probe) with an integrated raw data interface enables transmission of RF data (up to 40 megabytes per second). A 3D data set may contain up to 3 gigabytes, so that all of the high-resolution ultrasound information of the 2D image is available. Frame rates of up to 168 Hz result in temporal resolution 6 times that of standard 3D systems. The applicability of the system and the image quality were tested in 10 patients. The structure of the aortic valve and the dynamic changes were depicted by volume rendering. The changes in the orifice areas were measured in frame-by-frame planimetry. The mean number of frames recorded per cardiac cycle was 122 16. The improved structural resolution enabled a detailed imaging of the morphology of the aortic cusps. The rapid systolic movement patterns were recorded with up to 51 frames. The high number of frames enabled creation of precise area-time diagrams. Thus, the individual phases of aortic valve movement (rapid opening, slow valve closing, and rapid valve closing) could be analyzed quantitatively. Conclusion—A 3D system based on RF data enables high-resolution imaging of cardiac movement patterns. This offers new perspectives for qualitative and quantitative analyses, especially of cardiac valves. (Circulation. 2003;107:28762879.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New three-dimensional echocardiographic system using digital radiofrequency data--visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience.

BACKGROUND Common 3D systems have only limited spatial and temporal resolution (frame rate of 25 Hz). Thin structures such as cardiac valves are not imaged exactly; rapid movement patterns cannot be precisely recorded. The objective of the present project was to achieve radiofrequency (RF) data transmission to the 3D workstation to improve image resolution. METHODS AND RESULTS A commercially ...

متن کامل

Effect of digital elevation model’s resolution in producing flood hazard maps

Flooding is one of the most devastating natural disasters occurring annually in the Philippines. A call for a solution for this malady is very challenging as well as crucial to be addressed. Mapping flood hazard is an effective tool in determining the extent and depth of floods associated with hazard level in specified areas that need to be prioritized during flood occurrences. Precedent to the...

متن کامل

Three-dimensional printing of intracardiac defects from three-dimensional echocardiographic images: feasibility and relative accuracy.

BACKGROUND With the advent of three-dimensional (3D) printers and high-resolution cardiac imaging, rapid prototype constructions of congenital cardiac defects are now possible. Typically, source images for these models derive from higher resolution, cross-sectional cardiac imaging, such as cardiac magnetic resonance imaging or computed tomography. These imaging methods may involve intravenous c...

متن کامل

Doppler echocardiographic findings in tissue engineered aortic valve in a sheep model

Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...

متن کامل

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003