A generalized method for controlling end-tidal respiratory gases during nonsteady physiological conditions.
نویسندگان
چکیده
While forcing of end-tidal gases by regulating inspired gas concentrations is a common technique for studying cardiorespiratory physiology, independently controlling end-tidal gases is technically challenging. Feedforward control methods are challenging because end-tidal values vary as a dynamic function of both inspired gases and other nonregulated physiological parameters. Conventional feedback control is limited by delays within the lungs and body tissues and within the end-tidal forcing system itself. Consequently, modern end-tidal forcing studies have generally restricted their analysis to simple time courses of end-tidal gases and to resting steady-state conditions. To overcome these limitations, we have designed and validated a more generalized end-tidal forcing system that removes the need for manual tuning and rule-of-thumb based control heuristics, while allowing for accurate control of gases along spontaneous and complicated time courses and under nonsteady physiological conditions. On average during resting, steady walking, and walking with time varying speed, our system achieved step changes in PetCO2 within 3.0 ± 0.9 (mean ± SD) breaths and PetO2 within 4.4 ± 0.9 breaths, while also maintaining small steady-state errors of 0.1 ± 0.2 mmHg for PetCO2 and 0.3 ± 0.8 mmHg for PetO2 The system also accurately tracked more complicated changes in end-tidal values through a bandwidth of 1/10 the respiratory (sampling) frequency, a practical limit of feedback control systems. The primary mechanism enabling this controller performance is a generic mathematical model of the cardiopulmonary system that captures the breath-by-breath relationship between inspired and end-tidal gas concentrations, with secondary contributions from reduced delays in controlled air delivery.
منابع مشابه
Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital
Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...
متن کاملتأثیر تهویه با حجمهای جاری متفاوت و تهویه دقیقهای ثابت بر روی دیاکسید کربن انتهای بازدمی
Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2 and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...
متن کاملبررسی نیازهای توجهی کنترل الگوی تنفس و ارتباط آن با پیامدهای متابولیکی تنفس در افراد سالم
Objective: Normal breathing is essential for adjustment of natural metabolism of human body. Therefore, the aim of this study was to evaluate the control of breathing pattern in normal subjects both at rest and during cognitive loading. Materials & Methods: In this quasi-experimental study, 24 healthy subjects (14 males, 10 females) were selected by simple and convenient sampling. Spirometry...
متن کاملEvaluation of low tidal volume with positive end-expiratory pressure application effects on arterial blood gases during laparoscopic surgery.
BACKGROUND Pneumoperitoneum (PNP) and patient positions required for laparoscopy can induce pathophysiological changes that complicate anesthetic management during laparoscopic procedures. This study investigated whether low tidal volume and positive end-expiratory pressure (PEEP) application can improve ventilatory and oxygenation parameters during laparoscopic surgery. METHODS A total of 60...
متن کاملRecurrent Recruitment Manoeuvres Improve Lung Mechanics and Minimize Lung Injury during Mechanical Ventilation of Healthy Mice
INTRODUCTION Mechanical ventilation (MV) of mice is increasingly required in experimental studies, but the conditions that allow stable ventilation of mice over several hours have not yet been fully defined. In addition, most previous studies documented vital parameters and lung mechanics only incompletely. The aim of the present study was to establish experimental conditions that keep these pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 121 6 شماره
صفحات -
تاریخ انتشار 2016