Preanalytical management: serum vacuum tubes validation for routine clinical chemistry

نویسندگان

  • Gabriel Lima-Oliveira
  • Giuseppe Lippi
  • Gian Luca Salvagno
  • Martina Montagnana
  • Geraldo Picheth
  • Gian Cesare Guidi
چکیده

INTRODUCTION The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. MATERIALS AND METHODS Blood specimens from 100 volunteers in five different serum vacuum tubes (Tube I: VACUETTE, Tube II: LABOR IMPORT, Tube III: S-Monovette, Tube IV: SST and Tube V: SST II) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas 6000 module. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation. RESULTS AND CONCLUSIONS Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of the minimal preanalytical uncertainty for 15 clinical chemistry serum analytes.

BACKGROUND We sought a model to estimate preanalytical uncertainty of blood samples collected and processed by using optimal procedures. METHODS Optimal preanalytical handling of blood samples included use of a loosely fastened tourniquet, wide bore needles, recommended clotting time and centrifugation speed, and minimal storage before analysis. Blood was collected from each arm of 20 volunte...

متن کامل

Preanalytical aspects and sample quality assessment in metabolomics studies of human blood.

BACKGROUND Metabolomics is a powerful tool that is increasingly used in clinical research. Although excellent sample quality is essential, it can easily be compromised by undetected preanalytical errors. We set out to identify critical preanalytical steps and biomarkers that reflect preanalytical inaccuracies. METHODS We systematically investigated the effects of preanalytical variables (bloo...

متن کامل

Evaluation of the BD Vacutainer® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study

INTRODUCTION Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum ...

متن کامل

Effect of collection tube type and preanalytical handling on myeloperoxidase concentrations.

BACKGROUND Myeloperoxidase (MPO) has shown potential as a marker for cardiovascular disease. Limited studies have been published with a variety of sample types, resulting in a wide range of MPO values. Little is known or understood about the impact of collection tube type and preanalytical handling of specimens for MPO determination. METHOD MPO concentration was determined by use of the ARCHI...

متن کامل

Equimolar ammonia interference in potassium measurement on the Osmetech OPTI CCA: a reply.

gate collection tubes from various manufacturers, available evidence, including our data, indicates that these problems may be common. The more rapid coagulation process in clot-activator tubes may be associated with more extensive proteolysis in the specimen, potentially leading to greater protein fragmentation that is subsequently detected by mass spectrometry. Nonbiological changes, observed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2012