Intraocular lens calculation accuracy limits in normal eyes.

نویسندگان

  • Paul-Rolf Preussner
  • Thomas Olsen
  • Peter Hoffmann
  • Oliver Findl
چکیده

PURPOSE To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. SETTING Eye hospitals in Germany, Denmark, and Austria. METHOD Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was predicted by a simple scaling model based on measurements in 1 patient collective. The model was compared with 2 other approaches in 2 patient collectives at 2 hospitals (1121 eyes with 13 IOL models; 936 eyes with 2 models). Axial lengths were measured optically (IOLMaster, Zeiss). No parameter adjustments or individualization of IOL types or of surgeons/localizations were done. The prediction errors and measures of systematic bias for short or long eyes were used to quantify the outcome. RESULTS The mean prediction errors in the 2 collectives were +0.13 diopter (D) and -0.13 D and the mean absolute errors were 0.44 D and 0.50 D without bias for long or short eyes, but depending on the IOL position model approach. The differences in the mean prediction errors for the IOL types were below the allowed manufacturing tolerances and below human recognition thresholds. CONCLUSIONS The need to individualize and fudge parameters decreases with better physical models of the pseudophakic eye. Further improvements are possible by individual topography to extract corneal asphericity and measured pupil size to calculate the best focus, by improved position predictions based on individual measurements of the crystalline lens and by smaller tolerances for IOL manufacturing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Intraocular lens calculation for aspheric intraocular lenses.

PURPOSE To evaluate the possible benefits of biometry and ray-tracing intraocular lens (IOL) calculation for aspheric aberration-correcting IOLs. SETTING Private eye clinic in Germany. DESIGN Retrospective consecutive case series. METHODS Eyes with 3 different aberration-correcting IOLs were reviewed. Before surgery, the axial length, corneal thickness, anterior chamber depth, crystalline...

متن کامل

Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2008