Capabilities and limitations of pupil-plane filters for superresolution and image enhancement.

نویسندگان

  • Brynmor Davis
  • William Karl
  • Anna Swan
  • M Unlu
  • Bennett Goldberg
چکیده

The use of pupil-plane filters in microscopes has been proposed as a method of producing superresolution. Here it is shown that pupil-plane filters cannot increase the support of the transfer function for a large class of optical systems, implying that resolution cannot be improved solely by adding pupil-plane filters to an instrument. However, pupil filters can improve signal-to-noise performance and modify transfer-function zero crossing positions, as demonstrated through a confocal fluorescence example.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional superresolution by three-zone complex pupil filters.

Complex pupil filters are introduced to improve the three-dimensional resolving power of an optical imaging system. Through the design of the essential parameters of such filters, the transmittance and radius of the first zone, three-dimensional superresolution is realized. The Strehl ratio and the transverse and axial gains of such filters are analyzed in detail. A series of simulation example...

متن کامل

Distinct Modulated Pupil Function System for Real-Time Imaging of Living Cells

Optical microscopy is one of the most contributive tools for cell biology in the past decades. Many microscopic techniques with various functions have been developed to date, i.e., phase contrast microscopy, differential interference contrast (DIC) microscopy, confocal microscopy, two photon microscopy, superresolution microscopy, etc. However, person who is in charge of an experiment has to se...

متن کامل

Superresolution four-wave mixing microscopy.

We report on the development of a superresolution four-wave mixing microscope with spatial resolution approaching 130 nm which represents better than twice the diffraction limit at 800 nm while retaining the ability to acquire materials- and chemical- specific contrast. The resolution enhancement is achieved by narrowing the microscope's excitation volume in the focal plane through the combined...

متن کامل

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

Coherent superresolution imaging via grating-based illumination

This paper describes two superresolution coherent imaging techniques, which both use a diffraction grating to direct high spatial frequency information that would otherwise be lost through the imaging system pupil. The techniques employ digital holography to measure the optical field in the image plane and rely on capturing multiple holograms with the illumination condition altered between expo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 12 17  شماره 

صفحات  -

تاریخ انتشار 2004