Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.
نویسندگان
چکیده
PURPOSE The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. MATERIALS AND METHODS The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. RESULTS The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. CONCLUSIONS A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
منابع مشابه
Measurement of needle-tip bioimpedance to facilitate percutaneous access of the urinary and biliary systems: first assessment of an experimental system.
RATIONALE AND OBJECTIVES Percutaneous access to the renal collecting system or biliary system is most frequently performed under image guidance. However, current techniques lack a feedback mechanism to help confirm successful access. A percutaneous needle system has been developed consisting of a modified 18-gauge percutaneous access needle that measures tissue impedance at its needle tip. Init...
متن کاملLaparoscopic Assisted ultrasound guided Percutaneous Nephrolithotomy (PCNL) in Ectopic Pelvic Kidney
We report a patient with pain, abdominal palpable mass and a history of previous open renal stone surgery. Imaging studies showed a right pelvic kidney with multiple calyceal stones. We describe the successful management through laparoscopic assisted percutaneous nephrolithotomy with ultrasonography (PCNL) in ectopic pelvic kidney, stressing that this method is a minimally invasive therapeutic...
متن کاملPhase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کاملبررسی میزان موفقیت جراحی پرکوتانئوس در درمان سنگ کلیه بیماران مبتلا به ناهنجاریهای مادرزادی کلیوی
Background & Aim: Patients with congenital renal abnormality are more prone to calculus formation and have less chance of spontaneous stone passage. Percutaneous treatment of patients with calculi in an abnormal kidney can be challenging due to the altered anatomical relationship in the retroperitoneum. Therefore, we performed a review to assess the safety and efficacy of this minimally inv...
متن کاملStereotactic mechanical percutaneous renal access.
Obtaining accurate percutaneous renal access when treating intrarenal disease requires substantial skill. Robotic devices have been used in a variety of surgical applications and have been successful in facilitating percutaneous puncture while improving accuracy. Laboratory models of robotic devices for percutaneous renal access have also been developed. However, several technical hurdles need ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of urology
دوره 166 4 شماره
صفحات -
تاریخ انتشار 2001