چکیده

Optical microresonator biosensors have proven to be a valid tool for binding and affinity analysis of a biological binding event. However, when these microresonators are excited with a single optical mode they can not distinguish between a thin dense layer of biomolecules or a thick sparse layer. We succeeded in exciting a Silicon-on-Insulator (SOI) microring with both TE and TM polarisations simultaneously by using an asymmetrical directional coupler. A theoretical model is provided to solve the shifts of these modes to the thickness and refractive index of the biolayer. During a Bovine Serum Albumin (BSA) adsorption experiment, both shifts were tracked, showing the potential of the sensor for conformational analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An ultra-high-speed photonic temporal differentiator using cascaded SOI microring resonators

A high-speed photonic temporal differentiator based on cascaded SOI microring resonators is proposed and experimentally demonstrated in this study. The first-order all-optical differentiation functionality is realized through approaching the critical coupling condition of the cascaded microring resonators. A three-stage double channel side-coupled cascaded microring structure is used to provide...

متن کامل

Silicon-on-Insulator microring resonator for sensitive and label-free biosensing.

Label-free biosensors attempt to overcome the stability and reliability problems of biosensors relying on the detection of labeled molecules. We propose a label-free biosensor based on microring cavities in Silicon-on-Insulator (SOI) that fits in an area below 10x10mum(2). The resonance wavelength shift that occurs when the surroundings of a cavity is changed, is used for sensing. While theoret...

متن کامل

Ultrasensitive Detection of Testosterone Using Microring Resonator with Molecularly Imprinted Polymers

We report ultrasensitive and highly selective detection of testosterone based on microring resonance sensor using molecularly imprinted polymers (MIP). A silicon-on-insulator (SOI) micoring resonator was modified by MIP films (MIPs) on a surface. The MIPs was synthesized by thermopolymerization using methacrylic acid as functional monomer and ethylene glycol dimethacrylate as crosslinking agent...

متن کامل

Ultrafast all-optical wavelength conversion in Silicon- on-Insulator waveguides by means of Cross Phase

In this paper we report the ultrafast all-optical wavelength conversion in Silicon-onInsulator (SOI) waveguides. We used a pump-probe setup with 300 femtosecond pulses to demonstrate large temporal phase-shifts, caused by the Kerr effect and free carrier generation. Large wavelength shifts of a 1683nm probe signal have been observed. The wavelength conversion, ranging from 10nm redshifts to 15n...

متن کامل

Ultra-high Q and finesse all-pass microring resonators on Silicon-on-Insulator using rib waveguides

Low-loss rib waveguides on Silicon-on-Insulator are used to demonstrate ultra high-Q and finesse all-pass microring resonators with record finesse of 1100 and Q of 613000. Key words— Microring resonators, Silicon-on-Insulator (SOI)

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014