Kollarits 34 . 4 : An Eye - Contact CameralDisplay System for Videophone Applications Using a Conventional Direct - View LCD

نویسندگان

  • J. E Ribera
  • R. D. Gitlin
چکیده

An eye-contact display and camera system for video telephony is described in which a video camera looks through a conventional active matrix LC display. By removing the rear polarizer from the display, the camera can look through the display without seeing the information on the display. Display/camera multiplexing and color are achieved via a polarized projection illumination system. Color triads are projected through the LCD onto a PDLC shutter that acts as a switchable screen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid Crystals for Electro-optic Applications

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1. Electro-Optic Response of Liquid Crystals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. The Liquid Crystalline State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. Physical Properties of Liquid Crystals . . . . . . . . . . . . . . . . . . . . . . ....

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

A High Quality Autostereoscopy System Based on Time-Division Quadplexing Parallax Barrier

In this paper, we introduce a parallax barrier system that shows high definition autostereoscopy and holds wide viewing zone. The proposed method creates a 4-view parallax barrier system with full display resolution per view by setting aperture ratio to one quarter and using time-division quadplexing, then applies obtained 4-view to 2-view, so that the viewing zone for each eye becomes wider th...

متن کامل

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

Eye Activity Detection and Recognition Using Morphological Scale-Space Decomposition

Automatic recovery of eye gestures from image sequences is one of the important topics for face recognition and model-based coding of videophone sequences. Usually complicated models of the eye and its motion are used. In this contribution an eye gesture parameter estimation is described. A previously published automatic eye detection/tracking algorithm, based on template matching, is used for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995