Effect of topical anesthetics on intraocular pressure and pachymetry.
نویسندگان
چکیده
PURPOSE The determination of intraocular pressure (IOP) by noncontact tonometry (NCT) has been reported to be affected by central corneal thickness (CCT) and by the instillation of topical anesthetics. METHODS In order to determine the influence of topical anesthetics on CCT and IOP measured by NCT, 80 eyes from 49 patients were examined before and after the instillation of topical anesthetics. RESULTS Average age was 55.3 years (SD 18.4, range 18 to 93). Twenty-eight patients were female and 21 were male. Average basal IOP was 16.1 mmHg (SD 5.2, range 8 to 35.3). IOP was 14.8 mmHg (SD 4.6, 7.4 to 32.4) (p=0.0005, Student t test for paired data) 5 minutes after topical anesthetics instillation. CCT averaged 541 micronm (SD 32, range 482 to 604) before topical anesthetic drops and 541 micronm (SD 32, 490 to 607, p=0.89, Student t test for paired data) 5 minutes after topical anesthetics instillation. CONCLUSIONS The study confirms that the instillation of topical anesthetics causes a reduction in IOP. These changes do not seem to be associated with changes in CCT.
منابع مشابه
Effect of Calcium Channel Blockers on Intraocular Pressure in Rabbits
The objective of the study was to evaluate the antiglaucoma effect of calcium channel blockers diltiazem and verapamil. Albino rabbits were used and chronic glaucoma was induced in them using freshly prepared 150 units of alphachymotrypsin. 0.1 mL of drug solution was administered topically into the left eye whereas the right served as control. The pressure recording was carried out at 15, 30, ...
متن کاملInfluence of topical anesthesia on tonometric values of intraocular pressure.
The air pulse noncontact tonometer provides a safe and reliable method for measuring intraocular pressure (IOP), and makes it possible to avoid topical anesthesia. Based on previous reports that suggested possible anesthetic-induced IOP variations, this study was undertaken to investigate with this procedure the influence of local anesthetics on IOP and of some topically used drugs that could m...
متن کاملEffects of concomitant administration of latanoprost and pilocarpine on the intraocular pressure of experimentally glaucomatous rabbits
The purpose of this study was to evaluate the effects of a combination of latanoprost and pilocarpine onthe intraocular pressure in experimentally glaucomatous rabbits. Ocular hypertension was induced in 11conscious rabbits by the oral administration of tap water (70 mL/kg) via an orogastric tube. The study wasconducted in three therapeutic groups to test the effects of latanoprost (group L), p...
متن کاملEffects of latanoprost and pilocarpine combination on the intraocular pressure and pupil size of normal rabbits
The aim of this study was to determine the combination effect of latanoprost and pilocarpine on theintraocular pressure and pupil size in normal rabbits. In this study, 18 rabbits were randomized to threegroups of 6 animals each. The right eyes of rabbits in group 1 were treated topically with latanoprost, ingroup 2 with pilocarpine and in group 3 with latanoprost and pilocarpine. The left eyes...
متن کاملClinical comparison of the Icare tonometer and Goldmann applanation tonometry.
PURPOSE To compare a new method of intraocular pressure (IOP) measurement, using the Icare tonometer, with Goldmann applanation tonometry (GAT). PATIENTS AND METHODS Two observers obtained IOP readings in 292 eyes (143 right and 149 left) of 153 subjects, using the Icare without topical anesthetic. A GAT reading was subsequently obtained by a consultant ophthalmologist, without the knowledge ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2008