Respiratory Gating of Endoscopic OCT Images of the Upper Airway
نویسندگان
چکیده
Anatomical optical coherence tomography (aOCT) is an endoscopic imaging modality that can be used to quantify size and shape of the upper airway. We report the application of respiratory gating to aOCT images. Our results show that respiratory gating can reduce motion artefact in upper airway images. Using an error metric based on distance to the dominant reflection in each A-scan, we found notable improvements when the breath cycle was partitioned into approximately four gates, but only minor improvements as the number of gates was further increased.
منابع مشابه
Imaging of the pediatric airway using optical coherence tomography.
OBJECTIVES Optical coherence tomography (OCT) is an imaging modality that uses a broadband light source to produce high-resolution cross-sectional images in living tissue (8-20 microm). A prospective study of normal, benign, and pathologic tissues in the pediatric airway was conducted to assess the utility of OCT technology in characterizing the microanatomy of the pediatric upper aerodigestive...
متن کاملAn Unusual Cause of Dysphonia with Hemoptysis: A Laryngeal Live Leech
Introduction: Foreign bodies in the upper airway are one of the most challenging otolaryngology emergencies and have various presentations depending on their physical properties and location. Leeches are blood-sucking hermaphroditic worms that vary in color, length, and shape. They usually reside in fresh-water streams and lakes. When rural untreated water is drunk, leeches may localize in the...
متن کاملRespiratory gating of anatomical optical coherence tomography images of the human airway.
Anatomical optical coherence tomography (aOCT) is a long-range endoscopic imaging modality capable of quantifying size and shape of the human airway. A challenge to its in vivo application is motion artifact due to respiratory-related movement of the airway walls. This paper represents the first demonstration of respiratory gating of aOCT airway data, and introduces a novel error measure to gui...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملReal-time subglottic stenosis imaging using optical coherence tomography in the rabbit.
IMPORTANCE Subglottic stenosis (SGS) is a severe, acquired, potentially life-threatening disease that can be caused by endotracheal tube intubation. Newborns and neonates are particularly susceptible to SGS owing to the small caliber of their airway. OBJECTIVE To demonstrate optical coherence tomography (OCT) capabilities in detecting injury and scar formation using a rabbit model. Optical co...