Influence of the prostate volume, prostate specific antigen density and number of biopsy samples on prostate cancer detection.
نویسندگان
چکیده
AIM Establish the main differences in the prostate volume, prostate specific antigen density (PSAD), number of biopsy samples in patients with primarily or rebiopsy detected prostate cancer. MATERIALS AND METHODS In the 2007-2009 period, at the KCUS Urology Clinic, there were 379 TRUS guided prostate biopsies in 323 patients with known prostate volume. The total of 56 patients (17.3%) underwent the first rebiopsy, primarily due to precancerous lesions. The mean prostate volume, ranges of prostate size, PSAT, PSAD and the number of biopsy samples were analysed retrospectively, and the main characteristics in patients with primarily and rebiopsy diagnosed Pca were evaluated as well. RESULTS The first biopsy cancer detection rate was 29.6% (112/379). The rebiopsy detection rate was 30.3%. There was no statistically significant difference in the prostate volume and the number of biopsy samples among the total number of patients with prostate cancer against the group with benign (suspected) findings. There was a higher Pca detection rate in patients with the prostate volume < 40 cm3 and 40-60 cm3, against the group with the prostate volume > 60 cm3. PSAD was significantly higher in patients with PCa (0.24 vs. 0.18; p = 0.013). The total of 27.2% of the patients with negative biopsy findings and 48% of the patients with diagnosed Pca had PSAD > 0.15. PSAD showed sensitivity and specificity in prostate cancer detection of 50% and 75%, with PPV of 48%. Furthermore, the patients with PSAD >0.15 had a higher Gleason score versus the patients with PSAD < 0.15 (6.7 +/- 2.4 vs. 5.9 +/- 1.7; p < 0.003). A comparison of the main characteristics in patients with primarily and rebiopsy detected prostate cancer gave a statistically significant difference only in the number of biopsy samples (10.9 vs. 14.1, p <.0000). CONCLUSION Patients with a smaller prostate volume, lower PSAD and a higher number of biopsy samples in rebiopsy have a higher chance of prostate cancer detection. PSAD carries a higher specificity in rebiopsy decision, and a higher PSAD is related to a higher Gleason score.
منابع مشابه
Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men
Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...
متن کاملWhat is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?
Abstract Background: Regarding the variety of tests present for detecting and also screening prostate cancer and also bearing in mind the advantages and disadvantages of these tests we decided to re-evaluate these tests (total prostate specific antigen and all of its modifications) in detecting prostate cancer in men with intermediate serum PSAlevels. Methods: Following a cross se...
متن کاملمقایسه "نسبت PSA به حجم بافت بینابینی" با "دانسیتهPSA" در پیشگویی سرطان پروستات
Introduction: Prostatic specific antigen (PSA) is an excellent tumor marker, but it is not specific for prostate cancer. We evaluated the accuracy of PSA adjusted for transition zone volume calculated by transrectal ultrasonography in predicting prostate cancer in men compared with PSA density. Material and Methods: PSA adjusted for transition zone volume was obtained from 100 patients who u...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملتشخیص آنتیژن اختصاصی پروستات با استفاده از بیوسنسور الکتروشیمیایی مبتنی بر آپتامر
Background and Objectives: Detection of the biomarkers is one of the effective methods for diagnosis and treatment of prostate cancer. Prostate specific antigen (PSA) is currently the best biomarker available for controlling and detecting this cancer. The purpose of the current study was to design an electrochemical aptamer-based biosensor (electrochemical aptasensor) to measure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medicinski arhiv
دوره 66 1 شماره
صفحات -
تاریخ انتشار 2012