A simple method to test geometrical reliability of digital reconstructed radiograph (DRR)
نویسندگان
چکیده
In radiotherapy treatment portal images and digitally reconstructed radiographs (DRRs) are the most frequently used image-guidance systems to monitor patient set-up during clinical routine. DRR is therefore a critical element in the process of virtual simulation and patient position verification in radiotherapy. The aim of this work was to assess the geometric reliability of the DRR generated by XiO, Pinnacle, Odyssey and Ocentra-Masterplan Treatment Planning Systems (TPS). Instead of the Computed Tomography (CT) images of a quality assurance phantom two synthetic phantoms were created and used to asses the linearity and the ray tracing reliability of the DRR generators. The obtained results demonstrate that the linearity and the reliability of DRR generators was less than 1 pixel for all TPSs.
منابع مشابه
A Proposed Simple Teleradiology System Using a Digital Camera
Background & Aims: Teleradiology as an efficient way for avoiding unnecessary transfer of patients to special medical centers requires the images with digital format. However, in some developing countries, including Iran, imaging is being done using non digital devices. In such cases, changing analog images into digital ones can solve the problem. The method which is nowadays used for digita...
متن کاملDetection of patient setup errors with a portal image – DRR registration software application
The purpose of this study was to evaluate a custom portal image - digitally reconstructed radiograph (DRR) registration software application. The software works by transforming the portal image into the coordinate space of the DRR image using three control points placed on each image by the user, and displaying the fused image. In order to test statistically that the software actually improves ...
متن کاملAn intensity-based registration algorithm for probabilistic images and its application for 2-D to 3-D image registration
Registration of 2-D projection images and 3-D volume images is still a largely unsolved problem. In order to register a pre-operative CT image to an intra-operative 2-D x-ray image, one typically computes simulated x-ray images from the attenuation coefficients in the CT image (Digital Reconstructed Radiograph, DRR). The simulated images are then compared to the actual image using intensity-bas...
متن کاملInter- and Intra-observer Variability of a Cervical OPLL Classification Using Reconstructed CT Images
BACKGROUND The lateral radiograph-based system described by Tsuyama is used widely to classify ossification of the posterior longitudinal ligament (OPLL) of the cervical spine. However, OPLL is a complex 3-dimensional (3-D) lesion, not a simple and uniplanar one, which is often difficult to identify on a lateral radiograph. Furthermore, its reliability among spine surgeons has not been investig...
متن کاملMRI Visualisation by Digitally Reconstructed Radiographs
Visualising volumetric medical images such as computed tomography and magnetic resonance imaging (MRI) on picture archiving and communication systems (PACS) clients is often achieved by image browsing in sagittal, coronal or axial views or three-dimensional (3D) rendering. This latter technique requires fine thresholding for MRI. On the other hand, computing virtual radiograph images, also refe...
متن کامل