Comparison of low and intermediate source strengths for (125)I prostate brachytherapy implants.

نویسندگان

  • Nawaid Usmani
  • Kevin Martell
  • Sunita Ghosh
  • Harrison Moore
  • Nadeem Pervez
  • John Pedersen
  • Don Yee
  • Albert Murtha
  • John Amanie
  • Ron Sloboda
چکیده

PURPOSE To compare the implant quality and clinical outcomes for patients treated with low and intermediate strength (125)I seeds in prostate brachytherapy implants. METHODS AND MATERIALS This retrospective review included 390 consecutive patients treated with prostate brachytherapy from 1999 to 2006. The first 142 patients were implanted with source strengths lower than 0.415U (0.327mCi), with the subsequent 248 patients implanted with source strengths higher than 0.493U (0.388mCi). Clinical, dosimetric, toxicity, and outcome data were compared between these two cohorts of patients. RESULTS Despite having similar prostate volumes, fewer sources (median, 95 vs. 113; p<0.0001) and fewer needles (median, 23 vs. 29; p<0.0001) were implanted in the intermediate strength cohort. The postimplant dosimetry demonstrated better quality implants in patients treated with intermediate strength sources (median D90, 160.0Gy vs. 139.6Gy; p<0.0001), with greater dose inhomogeneity identified in the intermediate strength cohort of patients. A higher incidence of late rectal toxicity was identified in patients treated with intermediate strength sources despite lower rectal doses in this cohort. The biochemical relapse-free survival, prostate cancer survival, and overall survival were not significantly different between the two cohorts. CONCLUSIONS The transition from low to intermediate strength sources has led to fewer resources being used and improved postoperative dosimetry. Although there were more rectal complications identified in the intermediate strength cohort of patients in this analysis, there were no other significantly worse clinical or biochemical outcomes for patients implanted with intermediate strength sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cesium 131 versus iodine 125 implants for prostate cancer: evaluation of early PSA response.

INTRODUCTION Given the shorter half-life of cesium-131 (Cs-131) compared to iodine-125 (I-125), we hypothesized that initial PSA outcomes may differ. We compare initial PSA outcomes in men undergoing Cs-131 prostate brachytherapy to men treated with I-125. PATIENTS AND METHODS The first post-treatment PSA (obtained 3-6 months after the procedure) was compared in patients undergoing I-125 pros...

متن کامل

A comparison study on various low energy sources in interstitial prostate brachytherapy

PURPOSE Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. MATERIAL AND METHODS ProstaSeed (125)I brachytherapy sourc...

متن کامل

[Results of 125-iodine seed implant with preplanning system in 250 patients with prostate cancer].

INTRODUCTION We review the experience with prostate carcinoma patients treated with permanent implants of 125-I seeds and the outcome eight years after the beginning of this technique. MATERIAL AND METHODS From 2002 to 2007 we have performed 250 implants with LDR brachytherapy with RapidStrand(®) and preplanning system. Mean age was 68 (49-78). Mean PSA was 7.32 (2.31 - 14.6). T1-T2a was the ...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy

Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 12 5  شماره 

صفحات  -

تاریخ انتشار 2013