Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study.
نویسندگان
چکیده
BACKGROUND Flow quantification in real time by phase-contrast MRI (PC-MRI) may provide unique hemodynamic information in congenital heart disease, but available techniques have important limitations. We sought to validate a novel real-time magnetic resonance flow sequence in children. METHODS AND RESULTS In 14 pediatric patients (mean age 5.2+/-2.0 years) with cardiac left-to-right shunt, pulmonary (Q(p)) and aortic (Q(s)) flow rates were determined by nontriggered free-breathing real-time PC-MRI with single-shot echo-planar imaging combined with sensitivity encoding, which yielded 25 phase images per second at 2.7x2.7-mm in-plane resolution (field of view 30x34 cm2). Over a 9.5-second period that included 2 to 5 respiratory cycles, 16.6+/-2.6 subsequent stroke volumes (range 13 to 22) were acquired in each vessel. Results were compared with conventional retrospectively ECG-gated PC-MRI. Mean Q(p)/Q(s) by conventional PC-MRI was 1.91+/-0.64, and it was 1.94+/-0.68 (mean+/-SD) by real-time PC-MRI. For blood flow rate through pulmonary artery and aorta, we found differences of 2% to 3% (Bland-Altman analysis), with lower limits of agreement of -11% to -13% (mean-2 SD) and upper limits of 18% to 19% (mean+2 SD), which demonstrated good agreement between both methods. Mean difference for Q(p)/Q(s) was 1%, with limits of agreement ranging between -18% and 22% (mean+/-2 SD). High repeatability but some flow overestimation was observed in vitro (pulsatile flow phantom) with real-time PC-MRI, whereas conventional PC-MRI was accurate. Beat-to-beat stroke-volume variation was 6.1+/-2.3% in vivo and 3.7+/-0.3% in vitro. CONCLUSIONS Beat-to-beat quantification of pulmonary and aortic flows and hence left-to-right shunt within a few seconds is reliable by nontriggered real-time PC-MRI with echo-planar imaging and sensitivity encoding. Good spatial/temporal resolution and a large field of view may render the sequence valuable for multiple applications in congenital heart disease.
منابع مشابه
Real-time color-flow CMR in adults with congenital heart disease.
CMR is valuable in the evaluation of congenital heart disease (CHD). Traditional flow imaging sequences involve cardiac and respiratory gating, increasing scan time and susceptibility to arrhythmias. We studied a real-time color-flow CMR system for the detection of flow abnormalities in 13 adults with CHD. All 16 congenital flow abnormalities previously detected by echocardiography were visuali...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملImproved accuracy in flow mapping of congenital heart disease using stationary phantom technique
BACKGROUND Flow mapping by cardiovascular magnetic resonance has become the gold standard for non-invasively defining cardiac output (CO), shunt flow and regurgitation. Previous reports have highlighted the presence of inherent errors in flow mapping that are improved with the use of a stationary phantom control. To our knowledge, these studies have only been performed in healthy volunteers. ...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملMagnetic resonance phase-shift velocity mapping in pediatric patients with pulmonary venous obstruction.
OBJECTIVES This study evaluated the accuracy, advantages and clinical efficacy of magnetic resonance (MR) phase-shift velocity mapping, in delineating the site and the hemodynamic severity of pulmonary venous (PV) obstruction in patients with congenital heart disease (CHD). BACKGROUND Magnetic resonance phase-shift velocity mapping of normal pulmonary veins and of obstructed PV pathways have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 109 16 شماره
صفحات -