Region of Interest Reconstruction from Dose-Minimized Super Short Scan Data
نویسندگان
چکیده
In this paper, we investigate an ROI image reconstruction in super short scan. The redundant rays in such scan are further shielded by using dynamic collimation. The acquired data coming with an extremely minimized radiation dose are sufficient for image reconstruction. For compensating resulting truncation, we apply a recently proposed algorithm Approximated Truncation Robust Algorithm for Computed Tomography (ATRACT). The evaluation with two clinical datasets demonstrates that high image quality is achieved using this super short scan, with more dose reduction compared to a standard short scan.
منابع مشابه
A Cone-beam Reconstruction Algorithm for Dose-minimized Short Scan and Super Short Scan
Recently, we proposed an approach that deploys dynamic collimation to shield unnecessary redundant data in circular cone-beam data acquisition, enabling a dose-minimized short scan and super short scan. In this paper, we suggest a new reconstruction algorithm that produces images from these acquisitions that are superior to those restored by traditional short scan FDK-type algorithms. The metho...
متن کاملImpact of region of interest size and location in Gafchromic film dosimetry
Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of th...
متن کاملExact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.
In this paper, we present a new algorithm designed for a specific data truncation problem in fan-beam CT. We consider a scanning configuration in which the fan-beam projection data are acquired from an asymmetrically positioned half-sized detector. Namely, the asymmetric detector only covers one half of the scanning field of view. Thus, the acquired fan-beam projection data are truncated at eve...
متن کاملFeldkamp-type VOI reconstruction from super-short-scan cone-beam data.
Based on the fan-beam reconstruction formula recently developed by Noo et al. [Phys. Med. Biol. 47, 2525-2546 (2002)] we develop a Feldkamp-type algorithm for the reconstruction of a volume of interest (VOI) from super-short-scan data. With either a circular or spiral scanning locus in our VOI reconstruction scheme, we first estimate fan-beam data from cone-beam data using the popular "cosine c...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...